Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FXR CONSTRUCTION INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FXR CONSTRUCTION INC. in 535 ZEREGA AVE., BRONX, NY 10473 (NAICS 238110). OSHA activity number 340766047.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FXR Construction INC. — free Get an email when a new federal OSHA severe-injury report for FXR Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
535 ZEREGA AVE.
City
BRONX
State
NY
ZIP
10473
Mailing
99 JEFFERSON AVE, BAY SHORE, NY 11706
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
50
Ownership type
A

2 citations on file for this inspection.

1926.755 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 13, 2015
Abate by
Nov 21, 2015
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.755(b)(1): Anchor rods (anchor bolts) were field-modified without the approval of the project structural engineer of record:    Location: 535 Zerega Ave.    On or about: 5/19/15    a) Numerous anchor rods were field modified without the approval of the structural engineer. Anchor rods were not imbedded in to the concrete foundation to the depth specified in the engineering blueprints.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1926.755 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 13, 2015
Abate by
Nov 21, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.755(b)(2): Prior to the erection of columns, the controlling contractor did not provide written notification to the steel erector if there has been any modification of the anchor rods (anchor bolts) of those columns:    Location: 535 Zerega Ave.    On or about: 5/19/15    a) Numerous anchor rods were field modified without the approval of the structural engineer. Anchor rods were not imbedded in to the concrete foundation to the depth specified in the engineering blueprints. Written notification was not provided to the steel erector of field modifications prior to steel erection.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340766047.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.