BRONX, NY —
OSHA Inspection: FXR CONSTRUCTION INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FXR CONSTRUCTION INC. in 535 ZEREGA AVE., BRONX, NY 10473 (NAICS 238110). OSHA activity number 340766047.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FXR CONSTRUCTION INC.
- Site address
- 535 ZEREGA AVE.
- City
- BRONX
- State
- NY
- ZIP
- 10473
- Mailing
- 99 JEFFERSON AVE, BAY SHORE, NY 11706
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.755 B01
- Issued
- Oct 13, 2015
- Abate by
- Nov 21, 2015
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1926.755(b)(1): Anchor rods (anchor bolts) were field-modified without the approval of the project structural engineer of record: Location: 535 Zerega Ave. On or about: 5/19/15 a) Numerous anchor rods were field modified without the approval of the structural engineer. Anchor rods were not imbedded in to the concrete foundation to the depth specified in the engineering blueprints.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1926.755 B02
- Issued
- Oct 13, 2015
- Abate by
- Nov 21, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.755(b)(2): Prior to the erection of columns, the controlling contractor did not provide written notification to the steel erector if there has been any modification of the anchor rods (anchor bolts) of those columns: Location: 535 Zerega Ave. On or about: 5/19/15 a) Numerous anchor rods were field modified without the approval of the structural engineer. Anchor rods were not imbedded in to the concrete foundation to the depth specified in the engineering blueprints. Written notification was not provided to the steel erector of field modifications prior to steel erection.