Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BMI CAD SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BMI CAD SERVICES, INC. in 8A HERMAN DRIVE, SIMSBURY, CT 06070 (NAICS 332710). OSHA activity number 340766401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BMI CAD Services, INC. — free Get an email when a new federal OSHA severe-injury report for BMI CAD Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8A HERMAN DRIVE
City
SIMSBURY
State
CT
ZIP
06070
Mailing
P.O. BOX 522, SIMSBURY, CT 06070
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
15
Ownership type
A

11 citations on file for this inspection.

1910.215 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:   Surface Grinder Area:  On, or about, July 13, 2015, the hood guard provided on the Landis Tool surface grinder did not cover the flange projection.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.215 B05

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(5): The angular exposure of grinding wheel periphery and sides for safety guards used on surface grinding machine(s) employing the wheel periphery exceeded 150 degrees:  Surface Grinder Area:  On, or about, July 13, 2015, the hood  guard provided on the Landis Tool surface grinder allowed approximately 168 degrees of angular exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 28, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   CNC Workbench:  On, or about, July 13, 2015, the work rests provided on the DeWalt Model DW756 bench mounted off-hand grinder were not adjusted to within one eighth of an inch of the abrasive wheels.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.215 B09

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  CNC Workbench:  On, or about, July 13, 2015, the tongue guards provided on the DeWalt Model DW756 bench mounted off-hand grinder were not adjusted to within one quarter of an inch to the abrasive wheels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 4 exposed
Issued
Aug 28, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  A.  CNC Workbench:  On, or about, July 13, 2015, a relocatable power tap that was used to energize a grinder, belt sander and computer was energized through a series of extension cords.    B.  Bridgeport Area:  On, or about, July 13, 2015, a white pedestal fan provided for general ventilation was not designed for use in an industrial location in that it was not provided with a three wire hard service or junior hard service (round) cord.    C.  Saw Area:  On, or about, July 13, 2015, three power taps were used in series and in combination with several extension cords to energize equipment such as, but not limited to:  a Ridgid shop vac, a computer, a battery charger, a radio, the Rong Fu bandsaw and an overhead light fixture located on the mezzanine.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.147 C01

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2015
Abate by
Oct 16, 2015
Penalty
Initial $3,200 · Current $2,240 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  Shop Area:  On, or about, July 13, 2015, the employer had not developed and implemented a lockout/tagout program including specific procedures for multiple energy source equipment, hardware and employee training to protect employees during servicing and maintenance activities.  bmi CAD Serives, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 314405101, Citation Number 1, Item Number 1 and was affirmed as a final order on July 26, 2001, with respect to a workplace located at Simsbury, Connecticut.
Recent events (2)
  • — I (R) $2240
  • — Z (R) $3200

1910.212 A01

Repeat Gravity 5 7 instances 5 exposed
Issued
Aug 28, 2015
Abate by
Oct 16, 2015
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, rotating parts and flying chips:  On, or about, July 13, 2015, the following machines were not provided with adequate safeguarding:  A.  Saw Area:    1.  A blade guard was not provided on the unused portion of the blade on the Cosen Model MH-1016JA horizontal band saw. 2.  The Rong Fu horizontal band saw, Model S92285, was being used as a vertical bandsaw.  The spoked drive pulleys for the saw blade were exposed as well as all of the non-working portion of the blade.     B.  CNC Area:  The following machines were not provided with operable door interlocks in the automatic mode:  1.  CNC Lathe #1:  A Yang SML-20 CNC Turning Center. 2.  CNC Lathe #2:  A Yang SML-30 CNC Turning Center 3.  VMC#1:  A Yang SMV-1000 CNC milling center.  4.  VMC #2:  A Yang SMV-1000 CNC milling center. 5.  VMC #3:  A Yang SMV-1000 CNC milling center.  bmi CAD Services, Inc. was previously cited for a violation of an equivalent occupational safety and health standard [1910.212(a)(3)(ii)], which was contained in OSHA Inspection Number 314405101, Citation Number 1, Item Number 2b and was affirmed as a Final Order on July 26, 2011, with respect to a workplace located at Simsbury, Connecticut.
Recent events (2)
  • — I (R) $2800
  • — Z (R) $4000

1910.303 G01 II

Repeat 2 instances 10 exposed
Issued
Aug 28, 2015
Penalty
Initial $200 · Current $140 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Rear of Shop:  On, or about, July 13, 2015, a work table was positioned in front of the Square D and General Electric circuit breaker panels.  bmi CAD Services, Inc. was previously cited for a violation of an equivalent occupational safety and health standard [1910.303(g)(1)], which was contained in OSHA Inspection Number 314405101, Citation Number 2, Item Number 2 and was affirmed as a Final Order on July 26, 2011, with respect to a workplace located at Simsbury, Connecticut.
Recent events (2)
  • — I (R) $140
  • — Z (R) $200

1910.305 G01 IV A

Repeat Gravity 5 2 instances 4 exposed
Issued
Aug 28, 2015
Penalty
Initial $3,200 · Current $2,240 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  A.  CNC Workbench:  On, or about, July 13, 2015, three extension cords were run in series from a wall mounted receptacle, across the floor and to a workbench to energize a grinder, a belt sander and a computer.  B.  Saw Area:  On, or about, July 13, 2015, three power taps were used in series and in combination with several extension cords to energize equipment such as, but not limited to:  a Ridgid shop vac, a computer, a battery charger, a radio, the Rong Fu bandsaw and an overhead light fixture located on the mezzanine  bmi CAD Services, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 314405101, Citation Number 1, Item Number 4b and was affirmed as a final order on July 26, 2011, with respect to a workplace located at Simsbury, Connecticut.
Recent events (2)
  • — I (R) $2240
  • — Z (R) $3200

1910.253 B04 III

Other-than-serious 1 instance 4 exposed
Issued
Aug 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:  Saw Area:  On, or about, July 13, 2015, an acetylene cylinder was stored on a cart with an oxygen cylinder that was connected to a torch assembly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Aug 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    Saw Area:  On, or about, July 13, 2015, the power cord provided on the Cosen horizontal band saw, Model MH-1016JA, was pulled from the fitting on the side of the machine, exposing the inner conductors to damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BMI CAD Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340766401.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.