Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SILVERLEAF RESORTS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SILVERLEAF RESORTS, INC. in 2558 N 3653RD RD, SHERIDAN, IL 60551 (NAICS 721110). OSHA activity number 340774322.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Silverleaf Resorts, INC. for free Get an email when a new federal OSHA severe-injury report for Silverleaf Resorts, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2558 N 3653RD RD
City
SHERIDAN
State
IL
ZIP
60551
Mailing
2558 N 3653RD RD, SHERIDAN, IL 60551
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
301
Ownership type
Private (A)

5 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.146(c)(1):     The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    The employer failed to conduct an evaluation of the workplace to determine if any spaces were permit-required confined spaces; a collector tank (also referred to as a reservoir, surge tank, or surge pit) for the outdoor pool is a permit-required confined space.     Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.146 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.146(c)(2):     The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:    The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the collector tank (also referred to as a reservoir, surge tank, or surge pit), a component of the outdoor pool's circulation system.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.146 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.146(c)(4):     When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    The employer did not develop and implement a written permit space entry program for employee entry into the collector tank (also referred to as a reservoir, surge tank, or surge pit) for the outdoor pool.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.146 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Mar 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(1):     The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:    The employer did not provide training for employees to acquire the understanding, knowledge, and skills necessary associated with entry into the collector tank (also referred to as a reservoir, surge tank, or surge pit) for the outdoor pool, a permit required confined space.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.305(g)(1)(iv)(A):    Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    In the outdoor pool equipment area/pump room, a triple outlet flexible extension cord was used as a substitute for fixed wiring; the extension cord provided power to a wall-mounted reliable water chemistry control system and a box fan.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • · I (S) $2400
  • · Z (S) $4000

View Silverleaf Resorts, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340774322.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.