EASTON, PA —
OSHA Inspection: RANDOLPH MANUFACTURING, CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RANDOLPH MANUFACTURING, CORP. in 4 DANFORTH DRIVE PALMER INDUSTRIAL PARK, EASTON, PA 18045 (NAICS 332722). OSHA activity number 340775311.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RANDOLPH MANUFACTURING, CORP.
- Site address
- 4 DANFORTH DRIVE PALMER INDUSTRIAL PARK
- City
- EASTON
- State
- PA
- ZIP
- 18045
- Mailing
- 4 DANFORTH DRIVE PALMER INDUSTRIAL PARK, EASTON, PA 18045
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332722
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.215 B09
- Issued
- Oct 6, 2015
- Abate by
- Oct 19, 2015
- Penalty
- Initial $2,040 · Current $153 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Randolph Manufacturing, Corp. - On or about July 20, 2015, the left side of a Royal Oak brand cylindrical grinder did not have an adjustable tongue installed and exceeded 1/4 inch between the wheel and the end of the safety guard.
Recent events (2)
- — I (O) $153
- — Z (S) $2040
1910.303 B07 I
- Issued
- Oct 6, 2015
- Penalty
- Initial $1,734 · Current $1,734
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Randolph Manufacturing, Corp. - On or about July 20, 2015, openings in the electrical box of # 2 Davenport brand screw machine were not effectively closed. b) Randolph Manufacturing, Corp. - On or about July 20, 2015, openings in the electrical box of # 3 Davenport brand screw machine were not effectively closed. c) Randolph Manufacturing, Corp. - On or about July 20, 2015, openings in the electrical box of # 12 Davenport brand screw machine were not effectively closed. d) Randolph Manufacturing, Corp. - On or about July 20, 2015, openings in the electrical box of # 21 Davenport brand screw machine were not effectively closed.
Recent events (2)
- — I (S) $1734
- — Z (S) $1734
1910.147 C06 II
- Issued
- Oct 6, 2015
- Abate by
- Oct 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. a) Randolph Manufacturing, Corp. - On or about July 20, 2015, the employer's annual inspection of their energy control procedures did not identify the machine, inspection date, employees included, and the person performing the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332722)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340775311.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.