Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VEOLIA WATER TECHNOLOGIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VEOLIA WATER TECHNOLOGIES, INC. in 5 EARL COURT SUITE 100, WOODRIDGE, IL 60517 (NAICS 333319). OSHA activity number 340776285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veolia Water Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Veolia Water Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5 EARL COURT SUITE 100
City
WOODRIDGE
State
IL
ZIP
60517
Mailing
5 EARL COURT SUITE 100, WOODRIDGE, IL 60517
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333319
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.178 L02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 21, 2015
Abate by
Aug 23, 2015
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.    a) The employer did not ensure that each powered industrial operator had received training and a performance evaluation (driving test) in the workplace.  Employees were exposed to injury associated with struck-by and crushing hazards.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) Warehouse Area.  A relocatable power tap (power strip), which was not designed for use in an industrial environment, was used to supply power to an extension cord for a microwave, exposing employees to overloading and overheating of electrical components that could contribute to a fire.  There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340776285.