HIGHLANDS RANCH, CO —
OSHA Inspection: RELIABLE PLUMBING & HEATING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RELIABLE PLUMBING & HEATING LLC in 2074 E. COUNTY LINE LN, HIGHLANDS RANCH, CO 80126 (NAICS 238220). OSHA activity number 340779370.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RELIABLE PLUMBING & HEATING LLC
- Site address
- 2074 E. COUNTY LINE LN
- City
- HIGHLANDS RANCH
- State
- CO
- ZIP
- 80126
- Mailing
- 3870 SCHOOLWOOD CT., COLORADO SPRINGS, CO 80918
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Aug 26, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about July 15, 2015, employees were exposed to falls because the employer did not ensure that a ladder or some other safe means was used for egress from a 9 feet deep trench.
Recent events (1)
- — Z (S) $2000
1926.651 J02
- Issued
- Aug 26, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) On or about July 15, 2015, and at times prior, employees were exposed to injuries from falling excavated materials while working in a trench. The materials excavated from a 15 feet deep trench were piled at the edge of the trench and were not moved at least 2 feet from the edge.
Recent events (1)
- — Z (S) $1200
1926.652 A01
- Issued
- Aug 26, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $14,000 · Current $14,000
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) On or about July 15, 2015, and at times prior, employees were exposed to cave-ins while they worked in an excavation which was not protected from cave-ins by an adequate protective system. Employees worked in an excavation which was approximately 15 feet deep. The excavation had straight cut walls with an inadequate shielding system (trench box) that was too small for the depth of the excavation. Employees worked inside and outside of the shielding system. b) On or about July 15, 2015, employees were exposed to cave-ins while they worked in an excavation which was not protected from cave-ins by an adequate protective system. Employees worked in an excavation which was approximately 9 feet deep. The excavation had straight cut walls and no cave-in protective system was used.
Recent events (1)
- — Z (W) $14000
1926.651 H01
- Issued
- Aug 26, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: a) On or about July 15, 2015, and at times prior, employees were exposed to cave-ins while they worked in a trench which contained standing water and was not protected from cave-ins by an adequate protective system.
Recent events (1)
- — Z (W) $0
1926.651 K02
- Issued
- Aug 26, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(2): Where a competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions were taken to ensure their safety: a) On or about July 15, 2015, and at time prior, employees were exposed to cave-in hazards because the employer did not take precautions to remove employees that worked inside of two trenches (15 feet and 9 feet deep) which had straight cut walls and inadequate cave-in protection. Even after several small cave-ins in the deeper trench, the employer allowed employees to continue working in it.