Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALL STATE ELECTRIC LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALL STATE ELECTRIC LLC in 313 ROFF ST, PALISADES PARK, NJ 07650 (NAICS 238210). OSHA activity number 340783547.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL State Electric LLC — free Get an email when a new federal OSHA severe-injury report for ALL State Electric LLC is published. One employer, no account, unsubscribe in one click.
Site address
313 ROFF ST
City
PALISADES PARK
State
NJ
ZIP
07650
Mailing
147 STUART ST., PARAMUS, NJ 07652
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

2 citations on file for this inspection.

1910.333 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 10, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.333(c)(3): When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started:   a) Building Exterior - Overhead Service Line: Employee was exposed to electric shock while adjusting the overhead service line with a screw driver inserted between the energized cables, on or about 3/28/15.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.333 C07

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 10, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.333(c)(7): Portable ladders did not have non conductive siderails if they were used where the employee or the ladder could contact exposed energized parts.    a) Building Exterior - Overhead Service Line: Employee was exposed to electric shock while adjusting the overhead service line from an aluminum ladder that was supporting the electric line, on or about 3/28/15.