OSHA Inspection: L & G ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of L & G ROOFING, INC. in 1651 RAND ROAD, DES PLAINES, IL 60016 (NAICS 238160). OSHA activity number 340791078.

Watch L & G Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for L & G Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
L & G ROOFING, INC.
Site address
1651 RAND ROAD
City
DES PLAINES
State
IL
ZIP
60016
Mailing
7344 W. 57TH PLACE, SUMMIT, IL 60501
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.150 A04

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $0.00 Reduced
29 CFR 1926.150(a)(4): Defective firefighting equipment was not immediately replaced:   a) A discharged/empty portable fire extinguisher was provided for employee use where flammable and combustible materials were used on a roof deck during roofing work.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1926.150 C01 VI

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $2350.00
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:     a) The employer did not provide a fire extinguisher rated not less than 10B where more than 5 pounds of propane was provided for use and was being used during torch-down roofing operations.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2350
  • — Z (S) $0

1926.501 B10

Serious Gravity 10 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2350.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:      a) Employees were exposed to the hazard of falling approximately 14 feet from the edge of the roof deck while engaged in roofing activities without the use of fall protection or a safety monitoring system.         In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2350
  • — Z (S) $2800

1926.502 F01 III

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:        a) Warning lines were not used to create access paths connecting the work area to the point of access along the roof edge.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.503 B01

Other-than-serious 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:       a) The employer did not prepare written certification records related to employee fall protection training.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340791078.