DES PLAINES, IL —
OSHA Inspection: L & G ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of L & G ROOFING, INC. in 1651 RAND ROAD, DES PLAINES, IL 60016 (NAICS 238160). OSHA activity number 340791078.
Where did this inspection happen?
- Establishment
- L & G ROOFING, INC.
- Site address
- 1651 RAND ROAD
- City
- DES PLAINES
- State
- IL
- ZIP
- 60016
- Mailing
- 7344 W. 57TH PLACE, SUMMIT, IL 60501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.150 A04
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.150(a)(4): Defective firefighting equipment was not immediately replaced: a) A discharged/empty portable fire extinguisher was provided for employee use where flammable and combustible materials were used on a roof deck during roofing work. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.150 C01 VI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $2350.00
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: a) The employer did not provide a fire extinguisher rated not less than 10B where more than 5 pounds of propane was provided for use and was being used during torch-down roofing operations. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2350
- — Z (S) $0
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2350.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Employees were exposed to the hazard of falling approximately 14 feet from the edge of the roof deck while engaged in roofing activities without the use of fall protection or a safety monitoring system. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2350
- — Z (S) $2800
1926.502 F01 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) Warning lines were not used to create access paths connecting the work area to the point of access along the roof edge. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: a) The employer did not prepare written certification records related to employee fall protection training. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17
NAMICELA HOME SOLUTIONS INC
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
More inspections in IL
FRANKFORT, IL—2026-07-17
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17
PROFLOW PUMPING SOLUTIONS
Source