APOPKA, FL —
OSHA Inspection: MID FLORIDA FREEZER WAREHOUSES, LTD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MID FLORIDA FREEZER WAREHOUSES, LTD in 2560 WEST HWY 441, APOPKA, FL 32712 (NAICS 493120). OSHA activity number 340792134.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID FLORIDA FREEZER WAREHOUSES, LTD
- Site address
- 2560 WEST HWY 441
- City
- APOPKA
- State
- FL
- ZIP
- 32712
- Mailing
- 2560 WEST HWY 441, APOPKA, FL 32712
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 C01
- Issued
- Dec 11, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) At the establishment located on 2560 W. Hwy 441, Apopka, FL, employees engaged in the operation of the ammonia refrigeration system were provided and required the use of Survivair, full face, with dual ammonia cartridges, respirators, when handling events of "minor" ammonia discharge. No written policy program had been established, on or about, 07/21/2015.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.134 E01
- Issued
- Dec 11, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) At the establishment located on 2560 W. Hwy 441, Apopka, FL, employees engaged in the operation of the ammonia refrigeration system were provided and required the use of Survivair, full face, with dual ammonia cartridges, respirators, when handling events of "minor" ammonia discharge. No evaluation had been provided, on or about, 07/21/2015.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.134 F01
- Issued
- Dec 11, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) At the establishment located on 2560 W. Hwy 441, Apopka, FL, employees engaged in the operation of the ammonia refrigeration system were provided and required the use of Survivair, full face, with dual ammonia cartridges, respirators, when handling events of "minor" ammonia discharge. No fit testing had been provided, on or about, 07/21/2015.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.134 K
- Issued
- Dec 11, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (a) At the establishment located on 2560 W. Hwy 441, Apopka, FL, employees engaged in the operation of the ammonia refrigeration system were provided and required the use of Survivair, full face, with dual ammonia cartridges, respirators, when handling events of "minor" ammonia discharge. No annual training on the use and limitations had been provided, on or about, 07/21/2015.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.119 D03 I B
- Issued
- Dec 11, 2015
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams; (a) At the establishment located on 2560 W. Hwy. 441, Apopka, FL, the piping and instrumentation diagram (P&ID's) information of the ammonia refrigeration system was not kept up to date to include the changes to the system that included, but not limited to, the installation of Aircoil evaporators, on or about, 02/19/2013. No updated P&ID's were available, on or about, 07/21/2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at MID Florida Freezer Warehouses, LTD
View MID Florida Freezer Warehouses, LTD's full OSHA safety record →
More inspections in this industry (NAICS 493120)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340792134.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.