OSHA Inspection: GENERAL DYNAMICS ORDNANCE AND TACTICAL SYSTEMS INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL DYNAMICS ORDNANCE AND TACTICAL SYSTEMS INC in 156 CEDAR AVENUE, SCRANTON, PA 18505 (NAICS 336992). OSHA activity number 340792688.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Dynamics Ordnance and Tactical Systems INC — free Get an email when a new federal OSHA severe-injury report for General Dynamics Ordnance and Tactical Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
156 CEDAR AVENUE
City
SCRANTON
State
PA
ZIP
18505
Mailing
156 CEDAR AVENUE, SCRANTON, PA 18505
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336992
Employees
120
Ownership type
A

2 citations on file for this inspection.

1910.333 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2015
Abate by
Nov 18, 2015
Penalty
Initial $3,750 · Current $2,813 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not de-energized before the employee worked on or was near to them:    a) Production area: An employee sustained severe burn injuries from an arc flash while attempting to install conductors within an energized 480 volt bus duct plug in disconnect box, on or about July 17, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (S) $2812.5
  • — Z (S) $3750

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2015
Abate by
Nov 18, 2015
Penalty
Initial $3,750 · Current $2,813 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:    a) Production area: An employee sustained severe burn injuries from an arc flash while working in an energized 480 volt disconnect box without wearing appropriate electrical specific personal protective equipment, on or about July 17, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (S) $2812.5
  • — Z (S) $3750