TWIN LAKES, WI —
OSHA Inspection: SCHERRER CONSTRUCTION CO. INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SCHERRER CONSTRUCTION CO. INC. in 1218 WILMONT AVE., TWIN LAKES, WI 53181 (NAICS 236210). OSHA activity number 340796457.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHERRER CONSTRUCTION CO. INC.
- Site address
- 1218 WILMONT AVE.
- City
- TWIN LAKES
- State
- WI
- ZIP
- 53181
- Mailing
- 601 BLACKHAWK DRIVE, BURLINGTON, WI 53105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 51
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 F03
- Issued
- Dec 16, 2015
- Abate by
- Feb 4, 2016
- Penalty
- Initial $2,380 · Current $2,380
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. (a) Frequent and regular inspections of the job site were not conducted by a competent person to ensure hazardous situations were found and corrected.
Recent events (2)
- — I (S) $2380
- — Z (S) $2380
1926.451 B01
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) The working level of the supported scaffold was not fully planked between the front uprights and the guardrail supports.
Recent events (2)
- — I (S) $0
- — Z (S) $2380
1926.451 B10
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were modified in order to intermix them and a competent person did not determine that the resulting scaffold was structurally sound: (a) A competent person did not determine if a bakers scaffold with intermixed parts was structurally sound to work from prior to allowing employees to work from the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $1785
1926.451 G01
- Issued
- Dec 16, 2015
- Penalty
- Initial $2,380 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) Employees conducting masonry operations from a supported scaffold were not protected from falling to the lower level.
Recent events (2)
- — I (S) $1600
- — Z (S) $2380
1926.501 B01
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,380 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Employees conducting masonry activities from an elevated walking/working surface with an unprotected side or edge were not protected from falling to the lower level.
Recent events (2)
- — I (S) $1600
- — Z (S) $2380
1926.701 B
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: (a) Employees were exposed to impalement hazards posed by the unguarded and protruding reinforcing rod.
Recent events (2)
- — I (O) $0
- — Z (S) $2380
1926.1053 B01
- Issued
- Dec 16, 2015
- Penalty
- Initial $2,380 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) The portable ladder being used for access to the supported scaffold did not extend at least 3 feet above the working platform.
Recent events (2)
- — I (S) $1600
- — Z (S) $2380
More inspections at Scherrer Construction CO. INC.
View Scherrer Construction CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236210)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340796457.