Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GIROIR ENTERPRISES INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of GIROIR ENTERPRISES INCORPORATED in 455 COMMERCIAL DR., BUDA, TX 78610 (NAICS 327991). OSHA activity number 340798180.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Giroir Enterprises Incorporated — free Get an email when a new federal OSHA severe-injury report for Giroir Enterprises Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
455 COMMERCIAL DR.
City
BUDA
State
TX
ZIP
78610
Mailing
455 COMMERCIAL DR., BUDA, TX 78610
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
10
Ownership type
A

13 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  In the shop, where employees were operating automated edge shaper and polishing machinery, including the Pro-Edge III and IV, there was standing water on the floor around the saw and the base of the nearby Square D breaker box, which was supplying power to equipment including machinery, lights, and outlets, exposing employees to the hazards of slips, falls, and electrical shock.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.106 E02 IV A

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,200 · Current $720 Reduced

Hazardous substances 00402280

29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not kept in covered containers when not actually in use:  In the shop, where employees were fabricating granite countertops, flammable liquid containers were left open when not in use, including, but not limited to, 5-gallon cans of Nexus Adhesives 101 resin solution, Superior Transparent Knife Grade Adhesive, and DYNO High Performance Polyester Stone Adhesive, a 1-gallon jug of highly flammable Acetone, and a pint can of ICE Instant Color Enhancer, exposing employees to the hazards of fire.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.106 E09 III

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00402280

29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  In the shop, where employees were fabricating granite countertops, Scott Rags that were contaminated with combustible residue from flammable liquids and pastes were discarded in an open bin that was not emptied at the end of the shift, including, but not limited to, highly flammable Acetone, Nexus Adhesives 101 resin solution, Superior Transparent Knife Grade Adhesive, DYNO High Performance Polyester Stone Adhesive, ICE Instant Color Enhancer, and Tenax TeWax paste wax, exposing employees to the hazards of fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,600 · Current $960 Reduced

Hazardous substances 04352260

29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  In the shop, where employees were using corrosive Zep Industrial Purple Cleaner & Degreaser Concentrate for degreasing machinery, quick drenching or flushing facilities for the eyes and body were not provided, exposing employees to the hazards of corrosive chemical splashes.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.157 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,200 · Current $720 Reduced

Hazardous substances 00402280

29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  In the shop, where employees were using flammable liquids and waxes, and were expected to use fire extinguishers on incipient-stage fires and to evacuate when fires advanced beyond initial stage, Amerex and First Alert portable fire extinguishers were sitting on floors in unmarked locations, and access to the Amerex fire extinguisher was blocked by boxes and a shovel, exposing employees to the hazards of fire.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.157 C04

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00402280

29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  In the shop, where employees were using flammable liquids and waxes while fabricating granite counter tops, a portable Amerex 20-A:120-B:C fire extinguisher was partially discharged, exposing employees to the hazards of fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00402280

29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   In the shop, where employees were using flammable liquids and waxes while fabricating granite counter tops, a portable Amerex 20-A:120-B:C fire extinguisher lacked an inspection tag or record and was partially discharged, exposing employees to the hazards of fire.  Abatement Note: This standard applies to any extinguishers provided in the workplace. Maintenance check includes an internal examination, except extinguishers with stored pressure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,200 · Current $720 Reduced

Hazardous substances 00409010

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  At the inspection site, the employer did not develop and implement a written hazard communication program for employees who were generating silica-containing dust and using hazardous chemicals while fabricating granite countertops, including, but not limited to, highly flammable Acetone and Tenax TeWax, Nexus Adhesives 101 resin solution, corrosive Zep Industrial Purple Cleaner & Degreaser Concentrate, and Akemi Solid Wax, a suspect human carcinogen, exposing employees to the contact and inhalation hazards of chemicals.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.1200 G01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00409010

29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  At the inspection site, the employer did not have material safety data sheets where employees were generating silica-containing dust and using hazardous chemicals while fabricating granite countertops, including, but not limited to, highly flammable Acetone and Tenax TeWax, Nexus Adhesives 101 resin solution, DYNO High Performance Polyester Stone Adhesive, corrosive Zep Industrial Purple Cleaner & Degreaser Concentrate, and Akemi Solid Wax, a suspect human carcinogen, exposing employees to the contact and inhalation hazards of chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00409010

29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:  At the inspection site, chemical hazard communication training provided to employees did not include health hazards of chemical exposures in the workplace for employees who were generating silica-containing dust and using hazardous chemicals while fabricating granite countertops, including, but not limited to, highly flammable Acetone, Tenax TeWax, Nexus Adhesives 101 resin solution, corrosive Zep Industrial Purple Cleaner & Degreaser Concentrate, and Akemi Solid Wax, a suspect human carcinogen, exposing employees to the contact and inhalation hazards of chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious 1 instance 5 exposed
Issued
Dec 16, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 00402280

29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  In the shop, where employees were using flammable liquids while fabricating granite counter tops, access to the south exit door was blocked by wooden pallets, boxes, supplies and tools, exposing employees to the hazards of delayed egress and fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(c)(1):  In any workplace where respirators are necessary to protect employee health or whenever respirators are required by the employer, a written respiratory protection program that included the provisions in 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented:  In the shop, the employer did not develop and implement a written respiratory protection program for employees who were required to wear 3M 8511 N95 filtering facepiece respirators for protection from silica-containing dust while fabricating granite counter tops, exposing employees to physiological hazards associated with increased breathing resistance and inhalation hazards of silica-containing dust.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 6 exposed
Issued
Dec 16, 2015
Abate by
Dec 22, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  In the shop, airborne exposures were not identified and evaluated for employees who were required to wear 3M 8511 N95 filtering facepiece respirators for protection from silica-containing dust while fabricating granite counter tops, exposing employees to the inhalation hazards of silica-containing dust.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340798180.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.