Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RELIANCE STAFFING & RECRUITING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RELIANCE STAFFING & RECRUITING in 424 MARKET STREET, SUFFOLK, VA 23434 (NAICS 561320). OSHA activity number 340798834.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reliance Staffing & Recruiting — free Get an email when a new federal OSHA severe-injury report for Reliance Staffing & Recruiting is published. One employer, no account, unsubscribe in one click.
Site address
424 MARKET STREET
City
SUFFOLK
State
VA
ZIP
23434
Mailing
424 MARKET STREET, SUFFOLK, VA 23434
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561320
Employees
196
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 3, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures were not permanent and continuous:  a) 2500-D Warwick Blvd. Newport News, VA, 23607 at Virginia International Terminals, CrossGlobe Transport, Ltd. Warehouse "B" Loading Dock:  On or about 07-14-15 and times prior thereto, temporary employees of Reliance Staffing were using a 50 foot temporary extension cord with cord connectors and it was missing the grounding pin contact.  The cord set was plugged into a 6 inch right angle grinder.  The cord had other visible damaged areas with the outer jacket compromised exposing a black, white, and green ground wire contained within the temporary extension cord.  One area on the cord had visible energized conductor wires.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1926.404 B01 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 3, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection:  a) 2500-D Warwick Blvd. Newport News, VA, 23607 at Virginia International Terminals, CrossGlobe Transport, Ltd. Warehouse "B" Loading Dock:  On or about 07-14-15 and times prior thereto, a temporary employee of Reliance Staffing was using a 50 foot temporary extension cord with cord connectors powering a 6 inch right angled grinder and it was not protected by a GFCI Circuit.  Cord was plugged directly into warehouse shore power.  The cord had other visible damage with the outer jacket compromised exposing a black, white, and green ground wire contained within the temporary extension cord as well as a scraped area with an unprotected bare conductor wire visible.  The employer did not have an assured equipment grounding conductor program.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1926.416 E01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 3, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) 2500-D Warwick Blvd. Newport News, VA, 23607 at Virginia International Terminals, CrossGlobe Transport, Ltd. Warehouse "B" Loading Dock:  On or about 07-14-15 and times prior thereto, a temporary employee of Reliance Staffing was using a 50 foot temporary extension cord with cord connectors that was powering a 6 inch right angled grinder with a missing grounding pin contact.  Cord was damaged and had not been inspected in six months.  The cord had other visible damage with the outer jacket compromised exposing a black, white, and green ground wire contained within the temporary extension cord.  Bare energized conductor wires were visible on the cord.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

View Reliance Staffing & Recruiting's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340798834.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.