TULSA, OK —
OSHA Inspection: INDUSTRIAL SPLICING AND SLING, L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INDUSTRIAL SPLICING AND SLING, L.L.C. in 1842 N. 109TH E. AVE., TULSA, OK 74116 (NAICS 332999). OSHA activity number 340803550.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL SPLICING AND SLING, L.L.C.
- Site address
- 1842 N. 109TH E. AVE.
- City
- TULSA
- State
- OK
- ZIP
- 74116
- Mailing
- 1842 N. 109TH E. AVE., TULSA, OK 74116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 20
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 D01
- Issued
- Dec 2, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. On or about July 21, 2015, and times prior thereto, overhead storage area above sewing room was not marked with approved loads. Employees were exposed to the hazard of being struck by falling equipment and material.
Recent events (2)
- — I (S) $1300
- — Z (S) $2800
1910.36 D01
- Issued
- Dec 2, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $2,800 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: On or about July 21, 2015, and times prior thereto, employees were not able to open exit route doors from the inside at all times without keys, tools, or special knowledge. Three (3) doors were held shut by strap and wire or sling. Two doors on the south side of the building and one door on the west side of the building. Employees were exposed to the hazards associated with fire.
Recent events (2)
- — I (S) $1300
- — Z (S) $2800
1910.37 B02
- Issued
- Dec 2, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On or about July 21, 2015, and times prior thereto, exit door on the west side of the building were not marked with a sign reading "Exit". Employees were exposed to the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Dec 2, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: On or about July 21, 2015, and times prior thereto, each exit sign was not illuminated by a reliable light source distinctive in color. One (1) on south side of building, one (1) on the east side of building, and one (1) on the west side of building. Employees were exposed to the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Dec 2, 2015
- Abate by
- Dec 10, 2015
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): On or about July 21, 2015, and times prior thereto, flexible cord to foot pedal of coiling machine, cord was missing insulation and was bent in half. Black electrical tape was wrapped around the cord. Employees were exposed to the hazard of electric shock.
Recent events (2)
- — I (S) $1000
- — Z (S) $2100
1910.305 B01 II
- Issued
- Dec 2, 2015
- Abate by
- Dec 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about July 21, 2015, and times prior thereto, two circuit breaker boxes had unused knockouts left open. Employees were exposed to the hazard of electric shock and/or the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Dec 2, 2015
- Abate by
- Dec 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about July 21, 2015, and times prior thereto, fluorescent light fixture above Shop Manager's desk was wired to flexible extension cord, plugged into electrical outlet. Employees were exposed to the hazard of electric shock and/or the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Dec 2, 2015
- Abate by
- Dec 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about July 21, 2015, and times prior thereto, coiling machine, flexible cord used to power coiling machine was not provided with strain relief. Employees were exposed to the hazard of electric shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: On or about July 21, 2015, and times prior thereto, Sewing Room, employees using industrial sewing machines were not provided with and required to wear protective eye wear. Employees were exposed to the hazard of being struck by broken needles.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Dec 2, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about July 21, 2015, and times prior thereto, the employer did not develop, implement and maintain a written hazard communication program. Employees use substances such as, but not limited to, hot zinc. Employees were exposed to the hazards associated with breathing metal fumes.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332999)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340803550.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.