Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DILA DEVELOPMENT AND CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DILA DEVELOPMENT AND CONSTRUCTION in 1305 H ST., NE, WASHINGTON, DC 20002 (NAICS 236118). OSHA activity number 340804798.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dila Development and Construction — free Get an email when a new federal OSHA severe-injury report for Dila Development and Construction is published. One employer, no account, unsubscribe in one click.
Site address
1305 H ST., NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
1242 PENNSYLVANIA AVE., SE, WASHINGTON, DC 20003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 29, 2015
Abate by
Oct 3, 2015
Penalty
Initial $2,400 · Current $1,920 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure:     a)  Second Floor Stairway - On or about 04/29/2015 employees were exposed to a 10 foot fall through an unguarded 15 foot by 4 foot stair opening.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1920
  • — Z (S) $2400

1926.1052 C04

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 29, 2015
Penalty
Initial $1,200 · Current $960 Reduced
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps:          a)  Second Floor Stairway: On or about 04/29/2015 employees were exposed to a 10 foot fall from a stairway having more than four treads was not provided with a midrail, screen, mesh, intermediate vertical members, or equivalent intermediate structural members.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1200

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $1,600 · Current $1,280 Reduced
29 CFR 1926.1053(b)(1): Where portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:     a)  Fourth Floor - On or about 04/29/2015, two carpenters were exposed to a possible 10 foot fall from an aluminum extension ladder which projected 2.5 feet above the ladder landing and was not secured in place and provided with a grabrail.
Recent events (2)
  • — I (S) $1280
  • — Z (S) $1600

1926.1053 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:   a)  Second Floor Stairway  On or about 04/29/2015 employees were exposed to a fall from an aluminum extension ladder whose base was located 8 inches from a set of standard guardrails thereby restricting the safe access to the ladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Dila Development and Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340804798.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.