OSHA Inspection: BOULDER BRANDS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BOULDER BRANDS, INC. in 4735 FLORENCE STREET, DENVER, CO 80238 (NAICS 311811). OSHA activity number 340806330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boulder Brands, INC. — free Get an email when a new federal OSHA severe-injury report for Boulder Brands, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4735 FLORENCE STREET
City
DENVER
State
CO
ZIP
80238
Mailing
1600 PEARL STREET SUITE 300, BOULDER, CO 80302
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311811
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 7, 2016
Abate by
Jan 27, 2016
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:     (a) Boulder Brands, Inc. at 4735 Florence Street, Denver, Colorado 80238:  On or before July 9, 2015, as part of the injury/accident prevention responsibilities under its program, the employer did not ensure that an annual or more frequent inspection of the lockout/tagout procedures for equipment including, but not limited to, the Pizza Line Conveyor Equipment System was conducted to ensure that the procedure and the requirements of the energy control program were being followed.  On July 9, 2015 a sanitation employees arm was crushed by the ingoing nip point of the rotating drive rollers system while cleaning the moving conveyor drive rollers.  This condition exposed employees to the unexpected energizing, start up or release of stored energy.   Abatement Note:  The procedures and requirements of the periodic inspection of the energy control procedure shall include at a minimum:    (1)        The periodic inspection shall be performed by an authorized employee other than the one(s) utilizing the energy control procedure being inspected.    (2)        The periodic inspection shall be conducted to correct any deviations or inadequacies identified.    (3)        Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.    (4)        Where tagout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section.    (5)        The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.    Abatement Note:  Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (1)
  • — Z (S) $4250

1910.147 D02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 7, 2016
Abate by
Jan 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.  (a) Boulder Brands, Inc. at 4735 Florence Street, Denver, Colorado 80238:  On or before July 9, 2015, as part of the injury/accident prevention responsibilities under its program, the employer did not ensure that the pizza line conveyor equipment system was shut down using the Lockout/Tagout procedures established for the machine or equipment.  On July 9, 2015 a sanitation employees arm was crushed by the ingoing nip point of the rotating drive rollers system while cleaning the moving conveyor drive rollers.  This condition exposed employees to the unexpected start-up of hazardous energy   Abatement Note:  Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").