Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRUCE ELECTRICAL SERVICE, INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BRUCE ELECTRICAL SERVICE, INC in 8364 SHAWNEE COLLEGE RD, ULLIN, IL 62992 (NAICS 238210). OSHA activity number 340809037.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bruce Electrical Service, INC — free Get an email when a new federal OSHA severe-injury report for Bruce Electrical Service, INC is published. One employer, no account, unsubscribe in one click.
Site address
8364 SHAWNEE COLLEGE RD
City
ULLIN
State
IL
ZIP
62992
Mailing
708 EAST MAIN ST, MARION, IL 62959
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

4 citations on file for this inspection.

1910.333 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 19, 2016
Abate by
Jan 25, 2016
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee was exposed were not deenergized before the employee worked on or near them:      At the Shawnee Community College in Ullin, Illinois, while replacing lighting fixtures in the gymnasium, an employee was exposed to 286 volts that was powering the electrical lighting wiring.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.333 B02

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 19, 2016
Abate by
Jan 25, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(b)(2): While the employee was exposed to contact with live parts of fixed electrical equipment or circuits which have been de-energized, the circuits energizing the parts were not locked out or tagged out or both in accordance with the requirement in this paragraph.      At the Shawnee Community College gymnasium in Ullin, Illinois, while replacing light fixtures employees were exposed to 286 volt live and de-energized parts and the circuits energizing the parts were were not were not locked out or tagged out or both.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.333 B02 IV

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 19, 2016
Abate by
Jan 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(iv): The employer did not properly verify if the components were positively de-energized or in an otherwise safe condition to protect the employees from an electrical shock hazard.      At the Shawnee Community College gymnasium in Ullin, Illinois, the 286 volt lighting fixture circuits were not verified to ensure circuits had been positively de-energized or in an otherwise safe condition to protect the employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 19, 2016
Abate by
Jan 25, 2016
Penalty
Initial $5,000 · Current $4,000 Reduced
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:       At the Shawnee Community College in Ullin, Illinois, in the gymnasium, while working from a Genie GS-1930 scissors lift, the mid chain that is part of the end guardrail system, was not attached to the opposite guard rail while the employee was exposed to a fall hazard of up to 25 feet.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5000

View Bruce Electrical Service, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340809037.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.