NEWARK, NJ —
OSHA Inspection: EVEREST CONSTRUCTION CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EVEREST CONSTRUCTION CORP. in 115-121 HANFORD ST, NEWARK, NJ 07114 (NAICS 238160). OSHA activity number 340810241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EVEREST CONSTRUCTION CORP.
- Site address
- 115-121 HANFORD ST
- City
- NEWARK
- State
- NJ
- ZIP
- 07114
- Mailing
- 130 MITCHELL ST., WEST ORANGE, NJ 07052
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.403 B02
- Issued
- Sep 17, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Location: 115-121 Hanford St., Newark, NJ 07114 a) Employees used a portable light duty relocatable power tap to energize power tools while replacing a commercial roof; on or about 7/30/15.
Recent events (1)
- — Z (S) $1760
1926.404 B01 I
- Issued
- Sep 17, 2015
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Location: 115-121 Hanford St., Newark, NJ 07114. a) Employer did not provide a GFCI or an assured equipment grounding conductor program for employees utilizing a Makita circular saw that was powered by an extension cord; on or about 7/28/15.
Recent events (1)
- — Z (S) $2200
1926.404 F06
- Issued
- Sep 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous. Location: 115-121 Hanford St., Newark, NJ 07114 a) Employees used an extension cord that was missing the ground pin to power a Bosch circular saw. The circuit lacked a continuous path to ground; on or about 7/28/15.
Recent events (1)
- — Z (S) $0
1926.502 D15
- Issued
- Sep 17, 2015
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee. Location: 115-121 Hanford St., Newark, NJ 07114. a) Employees were not provided with an anchorage point capable of supporting at least 5,000 lbs. while replacing a commercial roof. The anchorage point lacked the required screws and two employees were tied off from the same anchorage point; on or about 7/28/15.
Recent events (1)
- — Z (S) $3080
1926.1053 B01
- Issued
- Sep 17, 2015
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. Location: 2115-121 Hanford St., Newark, NJ 07114 a)The ladder's side rails used to access the roof extended approximately 2 ft. above the landing surface. Employees were exposed to fall hazards of up to 20 ft. to the ground below; on or about 7/28/15.
Recent events (1)
- — Z (S) $2200
1926.501 B04 II
- Issued
- Sep 17, 2015
- Penalty
- Initial $15,400 · Current $15,400
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers. Location: 115-121 Hanford St., Newark, NJ 07114 a) An employee fell through an unprotected hole approximately 20 ft. to the ground below while installing roofing at the commercial building; on or about 7/26/15.
Recent events (1)
- — Z (W) $15400
1910.1200 E01
- Issued
- Sep 17, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(e), (g), and (h) will be met. Site: 115-121 Hanford St., Newark, NJ 07114 On or about 7/30/15; a) The employer did not implement and develop a written Hazard Communication Program for each employee exposed to bonding adhesive and resistol glue.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Sep 17, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use. Site: 115-121 Hanford St., Newark, NJ 07114 On or about 7/30/15; a) The employer did not maintained the Material Safety Data Sheets on site for the hazardous chemicals (bonding adhesive and resistol glue) being used.
Recent events (1)
- — Z (O) $0
1910.1200 H01
- Issued
- Sep 17, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. Location: 115-121 Hanford St., Newark, NJ 07114 On or about 7/30/15; a) The employer did not provide the employees with information and an effective training program for each employee exposed to adhesive bonding and resistol glue.
Recent events (1)
- — Z (O) $0
More inspections at Everest Construction Corp.
View Everest Construction Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340810241.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.