SCRANTON, PA —
OSHA Inspection: STERLING GLASS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STERLING GLASS, INC. in 1101 PENN AVE., SCRANTON, PA 18509 (NAICS 238150). OSHA activity number 340810589.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STERLING GLASS, INC.
- Site address
- 1101 PENN AVE.
- City
- SCRANTON
- State
- PA
- ZIP
- 18509
- Mailing
- 1101 PENN AVE., SCRANTON, PA 18509
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 25
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 21, 2015
- Abate by
- Nov 9, 2015
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crush-by and struck-by hazards while lifting loads with underhung cranes and overhead hoists. a) Production Area: Employees lifted loads that ranged in weight from 50 to 100 pounds with a Chisholm-Moore underhung crane and overhead hoist that have not been subjected to frequent and periodic inspections within the last twelve months, on or about July 29, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.37 A03
- Issued
- Oct 21, 2015
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Production Area: The exit door was observed to be obstructed by pieces of raw materials such as pieces of wood and metal parts, exposing employees to hazardous conditions, on or about July 29, 2015. CORRECTED DURING INSPECTION. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.212 A01
- Issued
- Oct 21, 2015
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Area: The blade of the Delta X Series Unisaw was not guarded, exposing employees to hazards caused by rotating parts on or about July 29, 2015. CORRECTED DURING INSPECTION. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.305 G02 II
- Issued
- Oct 21, 2015
- Penalty
- Initial $1,517 · Current $1,138 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Production Area: The flexible cable of the crane hoist control switch was spliced, employees were exposed to electrical hazards on or about July 29, 2015. CORRECTED DURING INSPECTION. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $1137.75
- — Z (S) $1517
1910.178 L04 III
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Workplace: An evaluation of each operator's performance was not being conducted at least once every three years, as observed on or about July 29, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Oct 21, 2015
- Abate by
- Nov 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At the facility: An employee was required to use a 3M half-face elastomeric respirator and a medical evaluation was not provided, on or about July 29, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Oct 21, 2015
- Abate by
- Nov 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) At the facility: An employee was not fit-tested prior to using a 3M half-mask respirator while cutting fiberglass plates on the Whirlwind up-cut saw, on or about July 29, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K03
- Issued
- Oct 21, 2015
- Abate by
- Nov 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) At the facility: An employee was not provided with adequate training on the usage of respirators while cutting fiberglass plates on the Whirlwind up-cut saw, on or about July 29, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Oct 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Superintendent's Office: An iPhone charger was plugged into an electrical outlet box which did not have a cover exposing employees to electrical hazards on or about July 29, 2015. CORRECTED DURING INSPECTION. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sterling Glass, INC.
View Sterling Glass, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238150)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340810589.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.