MONTROSE, CO —
OSHA Inspection: COSEY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COSEY, LLC. in 1710 N TOWNSEND AVE., MONTROSE, CO 81401 (NAICS 811198). OSHA activity number 340811330.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COSEY, LLC.
- Site address
- 1710 N TOWNSEND AVE.
- City
- MONTROSE
- State
- CO
- ZIP
- 81401
- Mailing
- 1710 N TOWNSEND AVE., MONTROSE, CO 81401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811198
- Employees
- 19
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 19, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards associated with improper automobile lift operations: (a) On or about July 29, 2015, and at times prior, Cosey, LLC., employees were exposed to crushing and struck-by hazards while working on automotive lifts as follows: 1 - Lifts were not inspected annually by a qualified lift inspector. 2 - Lifts were not inspected daily during use to ensure that they were properly maintained and functional. 3 - Lift #1 Did not have capacity labels, operator did not know its capacity. 4 - Lift #1 Was missing the padding on the swing-arm base. 5 - Lift #2 Worn out padding on the swing-arm bases. 6 - Lift #6 Locks on swing-arms do not engage. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.215 A01
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s): (a) On or about July 29, 2015, and at times prior, Cosey, LLC. did not ensure that abrasive wheels on grinding machines were used with safety guards. Employees were exposed to struck-by hazards, in that an 8" bench grinder was used without the required side and tongue guards. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.215 A04
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that the work rests on grinding machinery were adjusted closely to the wheel with a maximum opening of 1/8". Employees were exposed to struck-by hazards, in that an 8" stand-alone grinder was used without the work rest. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about July 29, 2015,and at times prior, Cosey, LLC., did not ensure that flexible cords and cables were connected to devices and fittings, so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminals. A 4-way, 110V receptacle mounted on the side of lift #2, showed signs of strain, inner wiring was visible, exposing employees to contact with electrical hazards. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.305 J01 I
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that receptacles located within 8 feet of the floor did not have live parts exposed to employee contact. Employees were exposed to contact with electrical hazards, in that 110-V receptacles in the service shop, and in the detailing area were broken, specific locations were: 1- West wall of station #2 2- East wall of station #4 3- West wall of detailing area. 4- Detailing area partition. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that electrical equipment had a work space clearance of at least 30 inches wide in front of such equipment. Access to an electrical panel in the service shop was blocked by a work table and other miscellaneous items. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 I
- Issued
- Aug 19, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by the standard. Several spray bottles with degreasers and acids were not labeled, exposing employees with contact with chemical hazards. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811198)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340811330.