Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COSEY, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COSEY, LLC. in 1710 N TOWNSEND AVE., MONTROSE, CO 81401 (NAICS 811198). OSHA activity number 340811330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cosey, LLC. — free Get an email when a new federal OSHA severe-injury report for Cosey, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
COSEY, LLC.
Site address
1710 N TOWNSEND AVE.
City
MONTROSE
State
CO
ZIP
81401
Mailing
1710 N TOWNSEND AVE., MONTROSE, CO 81401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
19
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 6 instances 3 exposed
Issued
Aug 19, 2015
Abate by
Sep 30, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards associated with improper automobile lift operations:    (a) On or about July 29, 2015, and at times prior, Cosey, LLC., employees were exposed to crushing and struck-by hazards while working on automotive lifts as follows:    1 - Lifts were not inspected annually by a qualified lift inspector.   2 - Lifts were not inspected daily during use to ensure that they were properly maintained and functional.  3 - Lift #1 Did not have capacity labels, operator did not know its capacity.  4 - Lift #1 Was missing the padding on the swing-arm base.  5 - Lift #2 Worn out padding on the swing-arm bases.  6 - Lift #6 Locks on swing-arms do not engage.         Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.215 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):    (a) On or about July 29, 2015, and at times prior, Cosey, LLC. did not ensure that abrasive wheels on grinding machines were used with safety guards. Employees were exposed to struck-by hazards, in that an 8" bench grinder was used without the required side and tongue guards.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.215 A04

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that the work rests on grinding machinery were adjusted closely to the wheel with a maximum opening of 1/8". Employees were exposed to struck-by hazards, in that an 8" stand-alone grinder was used without the work rest.     Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) On or about July 29, 2015,and at times prior, Cosey, LLC., did not ensure that flexible cords and cables were connected to devices and fittings, so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminals. A 4-way, 110V receptacle mounted on the side of lift #2, showed signs of strain, inner wiring was visible, exposing employees to contact with electrical hazards.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.305 J01 I

Serious Gravity 5 4 instances 4 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:  (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that receptacles located within 8 feet of the floor did not have live parts exposed to employee contact. Employees were exposed to contact with electrical hazards, in that 110-V receptacles in the service shop, and in the detailing area were broken, specific locations were:  1- West wall of station #2 2- East wall of station #4 3- West wall of detailing area. 4- Detailing area partition.   Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I

Other-than-serious 1 instance 6 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:  (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that electrical equipment had a work space clearance of at least 30 inches wide in front of such equipment. Access to an electrical panel in the service shop was blocked by a work table and other miscellaneous items.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 I

Other-than-serious 3 instances 6 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  (a) On or about July 29, 2015, and at times prior, Cosey, LLC., did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by the standard. Several spray bottles with degreasers and acids were not labeled, exposing employees with contact with chemical hazards.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340811330.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.