BUHL, ID —
OSHA Inspection: RANGEN CONNATURAL PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RANGEN CONNATURAL PRODUCTS in 115 13TH AVE, BUHL, ID 83316 (NAICS 115114). OSHA activity number 340819903.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RANGEN CONNATURAL PRODUCTS
- Site address
- 115 13TH AVE
- City
- BUHL
- State
- ID
- ZIP
- 83316
- Mailing
- P.O. BOX 706, BUHL, ID 83316
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115114
- Employees
- 65
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.272 J02 II
- Issued
- Sep 28, 2015
- Abate by
- Oct 23, 2015
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.272(j)(2)(ii): The employer did not immediately remove any fugitive grain dust accumulations whenever the level exceeded 1/8-inch at priority housekeeping areas, pursuant to the housekeeping program for grain elevators: a) Elevator #1: On or about 7-22-2015, employees were exposed to an excessive build up of combustible dust of 2-3" in some areas next to the #1 elevator leg, and boot. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2380
1910.242 B
- Issued
- Sep 28, 2015
- Abate by
- Oct 23, 2015
- Penalty
- Initial $1,517 · Current $759 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.: a) Mill main floor: On or about 7-22-2015, employees were exposed to a compressed air nozzle used for cleaning that was producing 96 PSI at the tip. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $758.5
- — Z (S) $1517
More inspections in this industry (NAICS 115114)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340819903.