Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHAEFER ENTERPRISES OF WOLF LAKE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SCHAEFER ENTERPRISES OF WOLF LAKE, INC. in 4535 NORTH STATE ROUTE 3, WOLF LAKE, IL 62998 (NAICS 423140). OSHA activity number 340820307.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schaefer Enterprises of Wolf Lake, INC. — free Get an email when a new federal OSHA severe-injury report for Schaefer Enterprises of Wolf Lake, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4535 NORTH STATE ROUTE 3
City
WOLF LAKE
State
IL
ZIP
62998
Mailing
4535 NORTH STATE ROUTE 3, WOLF LAKE, IL 62998
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423140
Employees
37
Ownership type
A

3 citations on file for this inspection.

1910.107 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 8, 2015
Abate by
Dec 14, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.107(b)(10):  Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit is located:  At the Spray Booth, two florescent lights installed within the spray booth area did not have the protective illumination panels.
Recent events (1)
  • — Z (S) $2380

1910.212 A05

Serious Gravity 5 3 instances 10 exposed
Issued
Dec 8, 2015
Abate by
Dec 18, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch:    a)  In the Back Shop area, east side, a direct drive 40 inch by 40 inch box fan, located on the floor was guarded with a wire mesh that had openings that were 1 inch by 2 inches.  Additionally, there was a front side 2 inch by 5 inch opening and a back side 2 inch by 6 inch opening in the mesh.     b)  In the Back Shop area, west side, a direct drive 40 inch by 40 inch box fan that had rollers, located on the floor, was guarded with a wire mesh that had openings that were 1 inch by 2 inches.   There was an additional 1 inch high, 23 inch wide slot between the guards.   c)  In the Back Shop area, mid-section, a direct drive fan 48 inch diameter was guarded with chicken mesh wire that had openings of 1 inch.
Recent events (1)
  • — Z (S) $2380

1910.215 A02

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 8, 2015
Abate by
Dec 18, 2015
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.215(a)(2):   Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:   In the Back Shop area, on a pedestal grinder, on the right wire brush side, the spindle guard was missing.
Recent events (1)
  • — Z (S) $1785