FOLEY, AL —
OSHA Inspection: BEBO'S EXPRESS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BEBO'S EXPRESS in 2300 MCKENZIE STREET, FOLEY, AL 36535 (NAICS 811192). OSHA activity number 340821727.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEBO'S EXPRESS
- Site address
- 2300 MCKENZIE STREET
- City
- FOLEY
- State
- AL
- ZIP
- 36535
- Mailing
- 3308 SPRINGDALE PLAZA ATTN: MR. DOUG KLYCE, MOBILE, AL 36606
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811192
- Employees
- 27
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.23 C01
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $3,600 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) On or about July 30, 2015 and times prior; fall hazard: The employer failed to ensure employees conducting replacement of gears on the miter curtain as they sat/straddled the frame, were protected from falls of 10 feet 4 inches to the concrete floor.
Recent events (2)
- — I (S) $2100
- — Z (S) $3600
1910.147 C01
- Issued
- Oct 9, 2015
- Abate by
- Nov 30, 2015
- Penalty
- Initial $4,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about July 30, 2015 and times prior; Lockout/Tagout program: The employer failed to ensure an energy control procedure was developed, trained employees, and conducted periodic inspections of the program for employees working on equipment such as but not limited to the miter section which has electric, water, and pneumatic energy sources.
Recent events (2)
- — I (S) $2100
- — Z (S) $4500
1910.151 C
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $2,295 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about July 30, 2015 and times prior; emergency eyewash: The employer failed to provide an emergency eyewash with 15 minutes of continue flow for employees mixing/using chemicals such as but not limited to Zep-A-Lube (corrosive & toxic) and CP&S Kryptonite (corrosive).
Recent events (2)
- — I (S) $2100
- — Z (S) $2295
1910.305 J02 IV
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $4,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) On or about July 30, 2015 and times prior; GFCI circuit: The employer failed to ensure an electrical 120v outlet in the maintenance area which has standing water is a GFCI outlet to protect employees from electrical hazards when they use it with an extension cord to the power the grinder.
Recent events (2)
- — I (S) $2100
- — Z (S) $4500
1910.1200 E01
- Issued
- Oct 9, 2015
- Abate by
- Nov 30, 2015
- Penalty
- Initial $2,700 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about July 30, 2015 and times prior; develop, hazard communication program: The employer failed to develop and implement a written hazard communication program for each employee exposed and/or using chemicals such as but not limited to Zep-A-Lube (corrosive & toxic), CP&S Pimp It, and CP&S Kryptonite (corrosive).
Recent events (2)
- — I (S) $2100
- — Z (S) $2700
1904.40 A
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $900 · Current $600 Reduced
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the OSHA 300 and 300a records within the four business hours: a) On or about July 30, 2015; 300 logs and 300a summary page: The employer failed to provide copies of the requested 300 logs for 2013-2015 and 300a summary page for 2013 and 2014 within four hours of the compliance officer asking for them.
Recent events (2)
- — I (O) $600
- — Z (O) $900
1910.305 B01 II
- Issued
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about July 30, 2015 and times prior; circuit breaker panel with missing blank: The employer failed to ensure a blank cover was installed on the opening of a missing breaker in the maintenance area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02
- Issued
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about July 30, 2015 and times prior, outlet cover in site managers office: The employer failed to ensure a proper cover was installed on a 120v outlet behind the coke culler.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors: a) On or about July 30, 2015 and times prior; Site Managers Office: The employer failed to ensure 120v electrical cord was properly installed in that a cord to a power strip ran from the oil lube office through the wall and connected to an outlet in the site managers office.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about July 30, 2015 and times prior; proper strain relief: The employer failed to ensure cable connection was maintained in that several strain relief had become disconnected throughout the carwash.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811192)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340821727.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.