MATTOON, IL —
OSHA Inspection: MATTOON PRECISION MANUFACTURING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MATTOON PRECISION MANUFACTURING, INC. in 2408 S. 14TH ST., MATTOON, IL 61938 (NAICS 336350). OSHA activity number 340824580.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATTOON PRECISION MANUFACTURING, INC.
- Site address
- 2408 S. 14TH ST.
- City
- MATTOON
- State
- IL
- ZIP
- 61938
- Mailing
- 2408 S. 14TH ST., MATTOON, IL 61938
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336350
- Employees
- 162
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Nov 6, 2015
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in activities covered by this section: Employees were exposed to the unexpected energization of the MHI Mitsubishi machines when clearing jams, retrieving fallen parts, or performing maintenance, because an energy control procedure had not been developed to address the energy sources used by the machine.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.147 C06 I
- Issued
- Nov 6, 2015
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. Employees were exposed to hazardous energy when performing servicing and maintenance tasks on the MHI Mitsubishi machines because the periodic inspection did not include a review of the energy control procedures for those machines.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
More inspections at Mattoon Precision Manufacturing, INC.