OSHA Inspection: FRITO-LAY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FRITO-LAY INC. in 1173 AIRPORT RD, ARKPORT, NY 14807 (NAICS 424450). OSHA activity number 340826262.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Frito-Lay INC. — free Get an email when a new federal OSHA severe-injury report for Frito-Lay INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FRITO-LAY INC.
Site address
1173 AIRPORT RD
City
ARKPORT
State
NY
ZIP
14807
Mailing
70 RIDGELAND ROAD, ROCHESTER, NY 14623
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424450
Employees
5
Ownership type
A

6 citations on file for this inspection.

1910.157 E03

Other-than-serious 1 instance 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.        a) At the Arkport Bin, on or about 8/5/2015: The fire extinguishers in each bay were not subjected to an annual       maintenance check, and the annual maintenance date was not recorded and retained as required.
Recent events (2)
  • — I (O) $2800
  • — Z (S) $2800

1910.157 G01

Other-than-serious 1 instance 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.        a) At the Arkport Bin, on or about 8/5/2015: The employer did not train its employees in fire extinguisher use and         hazards of incipient stage firefighting.         Abatement Note: By this date the employer must either correct the alleged violation(s) or implement a Fire Safety       Policy, as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR        1910.157(b).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.        a) At the Arkport Bin, on or about 8/5/2015: A Portable Fire Extinguisher was blocked by a filing rack and not available       for immediate use by employees.        b) At the Arkport Bin, on or about 8/5/2015: A Portable Fire Extinguisher was blocked by materials and was        not available for immediate use by employees.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 4 instances 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.        a) At the Arkport Bin, on or about 8/5/2015: Electrical outlet boxes were not properly installed, as they were       not enclosed or flushed with the finished surface.         b) At the Arkport Bin, on or about 8/5/2015: Electrical outlet box was held in place with duct tape and not rigidly       supported or properly secured.         c) At the Arkport Bin, on or about 8/5/2015: An electrical outlet box was not enclosed in the wall and the side and        back ends extended out into the work area.        d) At the Arkport Bin, on or about 8/5/2015: Electrical outlets were installed back-to-back within the same box.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.305 B02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.        a) At the Arkport Bin, on or about 8/5/2015: Electrical outlet boxes did not properly enclose live parts, as the boxes        did not have faceplates.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01 IV

Other-than-serious 1 instance 5 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.23(d)(1)(iv): Every flight of stairs having four or more risers shall be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: On stairways more than 44 inches wide but less than 88 inches wide, one handrail on each enclosed side and one stair railing on each open side.        a) At the Arkport Bin, on or about 8/5/2015: The stairway to the loading dock with four risers did not have a stair         railing on each open side.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

View Frito-Lay INC.'s full OSHA safety record →