CHARLESTON, WV —
OSHA Inspection: APPALACHIAN RENOVATIONS & PAINTING (ARP)
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of APPALACHIAN RENOVATIONS & PAINTING (ARP) in 123 WASHINGTON ST. WEST, CHARLESTON, WV 25302 (NAICS 238320). OSHA activity number 340828607.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPALACHIAN RENOVATIONS & PAINTING (ARP)
- Site address
- 123 WASHINGTON ST. WEST
- City
- CHARLESTON
- State
- WV
- ZIP
- 25302
- Mailing
- 303 WASHINGTON ST. WEST, CHARLESTON, WV 25302
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 21, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a.) Appalachian Renovations & Painting (ARP), 123 Washington St, Charleston WV: On or about 08/06/15, employees using a belt sander, miter saw, and nail gun were not wearing eye protection. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.150 C01 IV
- Issued
- Sep 21, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(iv): One or more fire extinguishers, rated not less than 2A, were not provided on each floor: a.) Appalachian Renovations & Painting (ARP), 123 Washington St., Charleston WV: On or about 08/06/15, the employer did not supply fire extinguishers for the site. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.404 B01 II
- Issued
- Sep 21, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a.) Appalachian Renovations & Painting (ARP), 123 Washington St. Charleston, WV: On or about 08/06/15, ground fault circuit interrupters were not provided to protect employees while using the 120 volt temporary power outlets to supply power to tools, such as, Black and Decker belt sander, Dewalt miter saw, and a Kobalt 5 gallon air compressor. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.404 F06
- Issued
- Sep 21, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a.) Appalachian Renovations & Painting (ARP), 123 Washington St. Charleston, WV: On or about 08/06/15, the path to ground for the 50' yellow extension cord used to supply power to the Black & Decker belt sander was not permanent and continuous in that, the ground prong was missing. b.) Appalachian Renovations & Painting (ARP), 123 Washington St. Charleston, WV: On or about 08/06/15, the path to ground for the 50' orange extension cord used to supply power to the Dewalt Miter Saw was not permanent and continuous in that, the ground prong was missing. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $960
- — Z (S) $1600