Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D & K PALLETS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of D & K PALLETS LLC in W395 N5656 FRONTIER ROAD, OCONOMOWOC, WI 53066 (NAICS 321920). OSHA activity number 340832278.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & K Pallets LLC — free Get an email when a new federal OSHA severe-injury report for D & K Pallets LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D & K PALLETS LLC
Site address
W395 N5656 FRONTIER ROAD
City
OCONOMOWOC
State
WI
ZIP
53066
Mailing
W395 N5656 FRONTIER ROAD, OCONOMOWOC, WI 53066
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
12
Ownership type
A

6 citations on file for this inspection.

1910.178 P01

Serious Gravity 1 2 instances 6 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)  (a) The Mitsubishi fork lift was missing a headlamp.  (b) The Mitsubishi forklift was missing the propane tank indexing pin. This pin is to assure proper positioning of the rotation of the cylindrical propane tank valve to prevent fuel release if the safety valve were caused to releave internal pressures.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.303 B02

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) An electrical outlet box on the north wall was not attached to the wall.  The box was more likely to be damaged and employees exposed to electrical and fire hazards.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 G01 IV A

Serious Gravity 1 1 instance 8 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) A relocatable power tap were used in place of permanent fixed wiring near the north door that powers a radio and radio antennae.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G06

Serious Gravity 5 2 instances 10 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels:    (a) The employer did not obtain an annual audiogram as part of the Hearing Conservation program.  An employee breaking and building pallets was exposed to an 8-hour time weighted average sound level of approximately 92.7 dBA or equivalently a dose of 145 percent during a 401 minute sampling period.   (b) The employer did not obtain an annual audiogram as part of a Hearing Conservation program. An employees breaking and building pallets was exposed an 8-hour time weighted average sound level of approximately 86.8 dBA or equivalently a dose of 64.6 percent during a 354 minute sampling period.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.242 B

Other-than-serious 1 instance 3 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  A compressed air of about 110 psi was used to clean sawdust and other particulates off clothing prior to breaks or end of shift.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H03 IV

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  (a) There had been no training implemented that described the new safety data sheet format and the new label elements that are contained within the globally harmonized system of classification and labeling of chemicals (GHS) for employees handling chemicals such as Tellus Premium Hydraulic Oil, Pennzoil motor oil. and propane.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View D & K Pallets LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340832278.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.