OCONOMOWOC, WI —
OSHA Inspection: D & K PALLETS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of D & K PALLETS LLC in W395 N5656 FRONTIER ROAD, OCONOMOWOC, WI 53066 (NAICS 321920). OSHA activity number 340832278.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & K PALLETS LLC
- Site address
- W395 N5656 FRONTIER ROAD
- City
- OCONOMOWOC
- State
- WI
- ZIP
- 53066
- Mailing
- W395 N5656 FRONTIER ROAD, OCONOMOWOC, WI 53066
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 P01
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) The Mitsubishi fork lift was missing a headlamp. (b) The Mitsubishi forklift was missing the propane tank indexing pin. This pin is to assure proper positioning of the rotation of the cylindrical propane tank valve to prevent fuel release if the safety valve were caused to releave internal pressures.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.303 B02
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) An electrical outlet box on the north wall was not attached to the wall. The box was more likely to be damaged and employees exposed to electrical and fire hazards.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) A relocatable power tap were used in place of permanent fixed wiring near the north door that powers a radio and radio antennae.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G06
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: (a) The employer did not obtain an annual audiogram as part of the Hearing Conservation program. An employee breaking and building pallets was exposed to an 8-hour time weighted average sound level of approximately 92.7 dBA or equivalently a dose of 145 percent during a 401 minute sampling period. (b) The employer did not obtain an annual audiogram as part of a Hearing Conservation program. An employees breaking and building pallets was exposed an 8-hour time weighted average sound level of approximately 86.8 dBA or equivalently a dose of 64.6 percent during a 354 minute sampling period.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.242 B
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) A compressed air of about 110 psi was used to clean sawdust and other particulates off clothing prior to breaks or end of shift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Dec 11, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) There had been no training implemented that described the new safety data sheet format and the new label elements that are contained within the globally harmonized system of classification and labeling of chemicals (GHS) for employees handling chemicals such as Tellus Premium Hydraulic Oil, Pennzoil motor oil. and propane.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at D & K Pallets LLC
View D & K Pallets LLC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340832278.