RIDGELAND, MS —
OSHA Inspection: J & S MASONRY SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J & S MASONRY SERVICE in 879 LAKE HARBOUR DR., RIDGELAND, MS 39157 (NAICS 238140). OSHA activity number 340833482.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & S MASONRY SERVICE
- Site address
- 879 LAKE HARBOUR DR.
- City
- RIDGELAND
- State
- MS
- ZIP
- 39157
- Mailing
- 76 OBED MAGEE ROAD, TYLERTOWN, MS 39667
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 11
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 B01 I
- Issued
- Sep 29, 2015
- Abate by
- Oct 1, 2015
- Penalty
- Initial $2,520 · Current $1,386 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) MugShots Bar & Grill - On or about July 30, 2015 employees were working from a welded framed tubular scaffolding using wood planking that had gaps between the boards that ranged from 1 inch to as wide as 17 inches.
Recent events (2)
- — I (S) $1386
- — Z (S) $2520
1926.451 B05 II
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $1,800 · Current $990 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end (a) MugShots Bar & Grill - On or about July 30, 2015 employees were working on a welded tubular scaffolding that is 21 feet long with the platform extending more than 18 inches outside edge of frames. The cantilevered portion of the platform was not guarded or supported to keep from tipping.
Recent events (2)
- — I (S) $990
- — Z (S) $1800
1926.451 B07
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur only over supports, and/or was less than 12 inches (30 cm) when the platforms were not nailed together or otherwise restrained to prevent movement. (a) MugShots Bar & Grill - On or about July 30, 2015 employees were working on scaffolding that had the platform splices overlapping less than 12 inches and located between the supports. The splices were not nailed together or fastened in a manner to prevent displacement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 II
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $2,520 · Current $1,386 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: (a) MugShots Bar & Grill - On or about July 30, 2015 at the interior east side of the building legs of the 21 feet long, 5 feet wide by 12 feet high scaffolding used in brick application operations was placed on wood planks on top of lower scaffolding in place of being on a level sound footing capable of supporting the scaffold without settling or displacement.
Recent events (2)
- — I (S) $1386
- — Z (S) $2520
1926.451 F07
- Issued
- Sep 29, 2015
- Abate by
- Oct 22, 2015
- Penalty
- Initial $2,520 · Current $1,386 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered by experienced and trained employees under the supervision of a competent person: (a) MugShots Bar & Grill - On or about July 30, 2015 the employees were working from welded tubular framed walk through scaffolding that were assembled by employees not supervised by a competent person.
Recent events (2)
- — I (S) $1386
- — Z (S) $2520
1926.451 G01
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $2,520 · Current $1,476 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section: (a) MugShots Bar & Grill - On or about July 30, 2015 employees were working from a welded tubular framed walk through scaffolding that was 12 feet 11 inches high with no guard rail system or a fall arrest system.
Recent events (2)
- — I (S) $1476
- — Z (S) $2520
1926.451 H02 II
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $1,800 · Current $990 Reduced
General-duty citation text
29 CFR 1926.451(h)(2)(ii): IAC 875 - Chapter 26 1926.451(h)(2)(ii): A toe board was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: (a) MugShots Bar & Grill - On or about July 30, 2015 scaffolding erected more than 12 feet high lacked toe boards. There were tool bags and work buckets sitting at the out side edge of the planks exposing employees to a struck by hazard.
Recent events (2)
- — I (S) $990
- — Z (S) $1800
1926.452 C02
- Issued
- Sep 29, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $2,520 · Current $1,386 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frame scaffold(s) were not properly braced by crossbracing or diagonal braces, or both, to secure vertical members laterally and to align them so that the erected scaffold was plumb, square, and rigid: (a) MugShots Bar & Grill - On or about July 30, 2015 employees were working from welded tubular frame scaffolding that was missing structural cross bracing. The center section of scaffolding on the west side of columns was missing cross bracing needed to tie in both ends of scaffolding to keep it plumb, square, and rigid.
Recent events (2)
- — I (S) $1386
- — Z (S) $2520
More inspections in this industry (NAICS 238140)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340833482.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.