WASHINGTON, DC —
OSHA Inspection: TRUMP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRUMP, INC. in 1620 RHODE ISLAND AVE., NE, WASHINGTON, DC 20018 (NAICS 811118). OSHA activity number 340835594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUMP, INC.
- Site address
- 1620 RHODE ISLAND AVE., NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20018
- Mailing
- 3100 DUKE ST., ALEXANDRIA, VA 22314
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811118
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 E02 IV A
- Issued
- Nov 24, 2015
- Abate by
- Dec 15, 2015
- Penalty
- Initial $1,200 · Current $700 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered containers when not in use: a) Storage Room On or about 08/06/2015, a five gallon portable gas can, containing approximately four gallons of gasoline, can was not closed while in storage. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $700
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Nov 24, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $1,200 · Current $700 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Service Bay No. 1 - On or about 08/07/2015, a 14 gauge, orange extension cord was attached to the building's concrete block wall by means of metal conduit clips. b) Storage Room - On or about 08/07/2015, a 14 gauge, orange extension cord was attached to the building's ceiling joists by means of nails. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $700
- — Z (S) $1200
1910.305 G01 IV D
- Issued
- Nov 24, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: a) Service Bay No. 1 - On or about 08/07/2015, a 14 gauge, orange extension cord was used in lieu of permanent wiring to power a radio. b) Storage Room - On or about 08/07/2015, a 14 gauge, orange extension cord was used in lieu of permanent wiring to power an Internet router. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 I
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: a) Storage Room - On or about 08/07/2015, compressed gas cylinders containing oxygen and acetylene gases were not separated by a half hour fire wall and were stored within eight inches of one another and within two feet of containers of gasoline and lubricating oil. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.132 A
- Issued
- Nov 24, 2015
- Abate by
- Dec 15, 2015
- Penalty
- Initial $400 · Current $100 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) Garage Bays On or about 08/06/2015, automobile mechanics working beneath vehicles elevated by hydraulic vehicle lifts were not provided with head protection while exposed to stuck-by hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $100
- — Z (O) $400
1910.132 D02
- Issued
- Nov 24, 2015
- Abate by
- Dec 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) Facility - On or about 08/07/2015, no written verification that a workplace hazard assessment for personal protective equipment had been performed by this employer applicable to workers engaged in motor vehicle repair operations. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Trump, INC.