CHARLESTON, WV —
OSHA Inspection: COREY BROTHERS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COREY BROTHERS, INC in 1410 LEWIS ST., CHARLESTON, WV 25301 (NAICS 424480). OSHA activity number 340838952.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COREY BROTHERS, INC
- Site address
- 1410 LEWIS ST.
- City
- CHARLESTON
- State
- WV
- ZIP
- 25301
- Mailing
- 1410 LEWIS ST., CHARLESTON, WV 25301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424480
- Employees
- 37
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.151 C
- Issued
- Sep 10, 2015
- Penalty
- Initial $2,380 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body was not provided within the work area for immediate emergency use: (a) Battery Charging Area Main Warehouse: An employee performs battery maintenance on several Yale 162G pallet jacks that are equipped with sulfuric acid batteries. The provided eyewash station was not filled with water as observed on August 11, 2015.
Recent events (2)
- — I (S) $1540
- — Z (S) $2380
1910.157 E03
- Issued
- Sep 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) Facility Wide: Portable fire extinguishers throughout the facility did not have the annual maintenance check in that they had not been checked since 2012-2013 as observed on August 11, 2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J01 I
- Issued
- Sep 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: (a) Elevator: A light containing a spiral fluorescent bulb located 7 foot 7 inches above the floor was not guarded to protect against employee contact to the light fixture and bulb, as observed on August 11, 2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.32 B03
- Issued
- Sep 10, 2015
- Penalty
- Initial $700 · Current $0 Reduced
General-duty citation text
29 CFR 1904.32(b)(3): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) was not properly certified: (a) Corey Brothers, Inc.: The 2014 Summary of Work-Related Injuries and Illnesses (OSHA 300A) was not properly certified in that the assistant controller had signed the form. The assistant controller is not a company executive as determined on August 11, 2015.
Recent events (2)
- — I (O) $0
- — Z (O) $700
More inspections at Corey Brothers, INC
View Corey Brothers, INC's full OSHA safety record →
More inspections in this industry (NAICS 424480)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340838952.