WAUKESHA, WI —
OSHA Inspection: A.L. SCHUTZMAN COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A.L. SCHUTZMAN COMPANY, INC. in N21 W23560 RIDGEVIEW PARKWAY, WAUKESHA, WI 53188 (NAICS 424490). OSHA activity number 340840560.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.L. SCHUTZMAN COMPANY, INC.
- Site address
- N21 W23560 RIDGEVIEW PARKWAY
- City
- WAUKESHA
- State
- WI
- ZIP
- 53188
- Mailing
- N21 W23560 RIDGEVIEW PARKWAY, WAUKESHA, WI 53188
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424490
- Employees
- 75
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I
- Issued
- Jan 27, 2016
- Abate by
- Feb 8, 2016
- Penalty
- Initial $5,670 · Current $3,969 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Employees were exposed to crushing hazards while cleaning the Marion Mixer - Mixer F (Model #SPS-2748 & Serial #94070) and the employer did not ensure the employees were fully trained and fully understood the purpose and function of the company's energy control program (lockout/tagout).
Recent events (2)
- — I (S) $3969
- — Z (S) $5670
1910.147 D02
- Issued
- Jan 27, 2016
- Abate by
- Feb 8, 2016
- Penalty
- Initial $5,670 · Current $3,969 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Employees cleaning the Marion Mixer - Mixer F (Model #SPS-2748 & Serial #94070) were exposed to crushing hazards and the employer did not ensure that the machine was properly shutdown and locked out.
Recent events (2)
- — I (S) $3969
- — Z (S) $5670
1910.305 A01 I
- Issued
- Jan 27, 2016
- Penalty
- Initial $2,430 · Current $1,701 Reduced
General-duty citation text
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity: (a) The flexible conduit on the Marion Mixer - Mixer F (Model #SPS-2748 & Serial #94070) was broken away from the connection fitting exposing electrical wiring and exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1701
- — Z (S) $2430
More inspections at A.L. Schutzman Company, INC.
View A.L. Schutzman Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424490)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340840560.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.