OSHA Inspection: A/X CARPENTRY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A/X CARPENTRY in 67 V ST., NW, WASHINGTON, DC 20006 (NAICS 236118). OSHA activity number 340840578.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A/X Carpentry — free Get an email when a new federal OSHA severe-injury report for A/X Carpentry is published. One employer, no account, unsubscribe in one click.
Establishment
A/X CARPENTRY
Site address
67 V ST., NW
City
WASHINGTON
State
DC
ZIP
20006
Mailing
4108 WARNER ST., KENSINGTON, MD 20895
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.1052 C01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 10, 2015
Abate by
Sep 30, 2015
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:   a)  On or about 08/11/2015, carpenters were exposed to a possible 10 foot fall hazard from a set of steps not provided with a handrail and which was used to access a building's second floor.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $1320

1926.1053 B04

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 10, 2015
Penalty
Initial $2,640 · Current $2,640
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed:   a)  Rear of House - On or about 08/11/2015, workers were exposed to a 6 foot fall from a 6 foot fiberglass portable step ladder that was folded together and which was used to gain access to the first floor of a building.              b)  Second Floor - On or about 08/11/2015, workers were exposed to a 10 foot fall from the top step of a 10 foot fiberglass portable step ladder that was folded together and which was used to gain access to the third floor deck.
Recent events (2)
  • — I (S) $2640
  • — Z (S) $2640

1926.1053 B13

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was allowed to be used as a step:   a)  Rear of House - On or about 08/11/2015, workers were exposed to a 6 foot fall from the top step of a 6 foot fiberglass portable step ladder which was used to gain access to the first floor of a building.              b)  Second Floor - On or about 08/11/2015, workers were exposed to a 10 foot fall from the top step of a 10 foot fiberglass portable step ladder which was used to gain access to the third floor deck.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 5 instances 3 exposed
Issued
Sep 10, 2015
Abate by
Sep 30, 2015
Penalty
Initial $15,400 · Current $7,000 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest system or another provision in paragraph (b) of this section which provides for an alternative fall protection measure:       a)  Second Floor - On or about 08/07/2015, two carpenters were not provided with fall protection and exposed to a 30 foot fall while walking on a 6 inch wide top plate of a wood framed wall.     b)  Third Floor Deck - On or about 08/11/2015, carpenters were not provided with fall protection and exposed to a 30 foot fall while installing plywood sheathing.     c)  Second Floor - On or about 08/11/2015, carpenters constructing wood framing were exposed to a 20 foot fall from a set of three window openings which had not been provided with fall protection.     d)  Second Floor - On or about 08/11/2015, carpenters constructing wood framing were exposed to a 25 foot fall from through a door opening which had not been provided with fall protection.     e)  Third Floor - On or about 08/13/2015, two carpenters were not provided with fall protection and exposed to a 40 foot fall while walking a 6 inch wide top plate of a wood framed wall.      A/X Carpentry, was also previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 316182872, citation number 1, item number 2 and was affirmed as a final order on 07/07/2012, with respect to a workplace located at 5420 Galena Pl., NW, Washington, DC 20016;     A/X Carpentry, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 951243, citation number 2, item number 1 and was affirmed as a final order on 04/07/2014, with respect to a workplace located at 2927 44 Pl., NW, Washington, DC 20005.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $15400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340840578.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.