OSHA Inspection: AWC FRAC VALVES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AWC FRAC VALVES in 64201 WINTERGREEN ROAD, LORE CITY, OH 43755 (NAICS 213112). OSHA activity number 340841667.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AWC Frac Valves — free Get an email when a new federal OSHA severe-injury report for AWC Frac Valves is published. One employer, no account, unsubscribe in one click.
Establishment
AWC FRAC VALVES
Site address
64201 WINTERGREEN ROAD
City
LORE CITY
State
OH
ZIP
43755
Mailing
64201 WINTERGREEN ROAD, LORE CITY, OH 43755
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 19, 2015
Abate by
Dec 1, 2015
Penalty
Initial $4,400 · Current $4,400
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder.  a.  At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, the employer allowed employees to stand on the back side of a Toyota forklift to increase their working height to hit packing on valve stems with a sledge hammer, thereby exposing employees to a four feet fall hazard.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $4400

1910.334 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 19, 2015
Abate by
Dec 24, 2015
Penalty
Initial $5,500 · Current $3,850 Reduced
29 CFR 1910.334(b)(2): Reclosing circuits after protective device operation. After a circuit is deenergized by a circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized. The repetitive manual reclosing of circuit breakers or reenergizing circuits through replaced fuses is prohibited.     a.  At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, employees repetitively reclosed circuit breakers to reenergize circuits that were deenergized by circuit protective devices, thereby exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $3850
  • — Z (S) $5500

1910.303 B02

Other-than-serious 1 instance 6 exposed
Issued
Nov 19, 2015
Abate by
Dec 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  a.  At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, in the valve washing area, a metallic outlet box was used as an extension cord located on the floor, therefore not used in accordance with the UL listing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340841667.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.