LORE CITY, OH —
OSHA Inspection: AWC FRAC VALVES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AWC FRAC VALVES in 64201 WINTERGREEN ROAD, LORE CITY, OH 43755 (NAICS 213112). OSHA activity number 340841667.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AWC FRAC VALVES
- Site address
- 64201 WINTERGREEN ROAD
- City
- LORE CITY
- State
- OH
- ZIP
- 43755
- Mailing
- 64201 WINTERGREEN ROAD, LORE CITY, OH 43755
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Nov 19, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. a. At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, the employer allowed employees to stand on the back side of a Toyota forklift to increase their working height to hit packing on valve stems with a sledge hammer, thereby exposing employees to a four feet fall hazard.
Recent events (2)
- — I (S) $4400
- — Z (S) $4400
1910.334 B02
- Issued
- Nov 19, 2015
- Abate by
- Dec 24, 2015
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.334(b)(2): Reclosing circuits after protective device operation. After a circuit is deenergized by a circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized. The repetitive manual reclosing of circuit breakers or reenergizing circuits through replaced fuses is prohibited. a. At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, employees repetitively reclosed circuit breakers to reenergize circuits that were deenergized by circuit protective devices, thereby exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $3850
- — Z (S) $5500
1910.303 B02
- Issued
- Nov 19, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a. At the workplace located at 64201 Wintergreen Road, Lore City, Ohio, in the valve washing area, a metallic outlet box was used as an extension cord located on the floor, therefore not used in accordance with the UL listing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 213112)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340841667.