AUSTIN, TX —
OSHA Inspection: FLOORING SOLUTIONS, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of FLOORING SOLUTIONS, INC. in 320 CAPITAL OF TEXAS HWY., AUSTIN, TX 78746 (NAICS 238340). OSHA activity number 340841816.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLOORING SOLUTIONS, INC.
- Site address
- 320 CAPITAL OF TEXAS HWY.
- City
- AUSTIN
- State
- TX
- ZIP
- 78746
- Mailing
- 8606 WALL ST. BLDG. 16, AUSTIN, TX 78754
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238340
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1200 E01
- Issued
- Sep 30, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $2,800 · Current $2,800
0577
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) At the construction site located at 320 Capitol of Texas Highway in Austin, Texas, on or about July 10, 2015, and in times prior thereto, the employer's hazard communication program was not implemented in that employees who were using chemicals such as alkaline Laticrete 4-XLT Tile And Stone Adhesive powder had not seen any written information on the chemical other than label information, and were not aware of the location of the written hazard communication program or material safety data sheets, exposing employees to the hazards of alkaline chemical contact, including alkali burns.
Recent events (1)
- — Z (S) $2800
1910.1200 H03 IV
- Issued
- Sep 30, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
0577
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information: (Construction Reference: 1926.59) At the construction site located at 320 Capitol of Texas Highway in Austin, Texas, on or about July 10, 2015, and in times prior thereto, hazard communication training did not include how to read a material safety data sheet for employees who were mixing alkaline Laticrete 4-XLT Tile And Stone Adhesive powder and setting tile, exposing employees to the hazards of alkaline chemical contact, including alkali burns.
Recent events (1)
- — Z (S) $0
1926.50 G
- Issued
- Sep 30, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
0577
General-duty citation text
29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: At the construction site located at 320 Capitol of Texas Highway in Austin, Texas, on or about July 10, 2015, and in times prior thereto, eyewash facilities for quick flushing of the eyes/face were not provided for employees who were mixing alkaline Laticrete 4-XLT Tile And Stone Adhesive powder, exposing employees to the hazards of alkaline chemical splashes, including alkali burns.
Recent events (1)
- — Z (S) $0
1926.102 A01
- Issued
- Sep 30, 2015
- Abate by
- Oct 6, 2015
- Penalty
- Initial $0 · Current $0
0577
General-duty citation text
29 CFR 1926.102(a)(1): Eye and/or face protective equipment was not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: (a) At the construction site located at 320 Capitol of Texas Highway in Austin, Texas, on or about July 10, 2015, and in times prior thereto, safety glasses with side shields were provided in lieu of chemical splash goggles or faceshield for employees who were mixing alkaline Laticrete 4-XLT Tile And Stone Adhesive powder, exposing employees to the hazards of alkaline chemical splashes, including alkali burns. (b) At the construction site located at 320 Capitol of Texas Highway in Austin, Texas, on July 10, 2015, where employees were scoring and snapping 13-inch x 13-inch porcelain tile and installing tile overhead on shower walls, the employer did not ensure that employees wore personal protective equipment for eyes and/or face, exposing employees to the hazards of being struck by tile pieces.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238340)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340841816.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.