LITTLE NECK, NY —
OSHA Inspection: ITM CONSTRUCTION CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ITM CONSTRUCTION CORP. in 5018 MARATHON PARKWAY, LITTLE NECK, NY 11362 (NAICS 238320). OSHA activity number 340842707.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ITM CONSTRUCTION CORP.
- Site address
- 5018 MARATHON PARKWAY
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11362
- Mailing
- 30-05 30TH AVE., ASTORIA, NY 11102
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Sep 22, 2015
- Abate by
- Sep 28, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) At the worksite - Employees painting a house were from a tubular welded scaffold were each standing on a single plank; on or about 08/11/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 E01
- Issued
- Sep 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) On a tubular welded scaffold - Employees used the frame to go up and down; on or about 08/11/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- Sep 22, 2015
- Abate by
- Sep 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally (a) At the work site - A tubular welded scaffolds was missing a diagonal cross braces; on or about 08/11/15. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Sep 22, 2015
- Abate by
- Sep 28, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. (a) At the worksite - Employees working on a tubular welded scaffold painting a house were not protected from falling; on or about 08/11/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.454 A
- Issued
- Sep 22, 2015
- Abate by
- Oct 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the worksite - Employees engaged in painting a house working from a tubular welded scaffold that was not fully planked, climbed the scaffold frame for access, did not have guardrails and was missing a diagonal cross brace; on or about 08/11/15. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Sep 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) At the worksite - An employee was standing directly beneath another employee painting a house from a scaffold. No hard hat was provided; on or 08/11/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238320)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340842707.