BOGART, GA —
OSHA Inspection: IRON MAN MIZE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IRON MAN MIZE, LLC in 2200 MOORES FORD RD, BOGART, GA 30622 (NAICS 332323). OSHA activity number 340845262.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IRON MAN MIZE, LLC
- Site address
- 2200 MOORES FORD RD
- City
- BOGART
- State
- GA
- ZIP
- 30622
- Mailing
- 2200 MOORES FORD RD, BOGART, GA 30622
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A02
- Issued
- Sep 17, 2015
- Penalty
- Initial $1,445 · Current $860 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: Iron Man Mize, LLC, Bogart, GA - The lower portion of the blade on the chop saw used to cut metal was not guarded, on or about 8/13/15.
Recent events (2)
- — I (S) $860
- — Z (S) $1445
1910.253 B04 III
- Issued
- Sep 17, 2015
- Penalty
- Initial $867 · Current $520 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: Iron Man Mize, LLC, Bogart, GA - Oxygen and acetylene gas cylinders were stored together, on or about 8/13/15.
Recent events (2)
- — I (S) $520
- — Z (S) $867
1910.303 G02 I
- Issued
- Sep 17, 2015
- Abate by
- Oct 14, 2015
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Iron Man Mize, LLC, Bogart, GA - The two electrical panels located in the storage room had breakers missing and were not enclosed to prevent accidental contact with live parts, on or about 8/13/15.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.1200 E01
- Issued
- Sep 17, 2015
- Abate by
- Oct 14, 2015
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Iron Man Mize, LLC, Bogart, GA - During the manufacturing of ornamental iron products, employees handled material such as but not limited to metal and welding gasses. A written hazard communication program had not been developed, on or about 8/13/15.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.1200 H01
- Issued
- Sep 17, 2015
- Abate by
- Oct 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Iron Man Mize, LLC, Bogart, GA - During the manufacturing of ornamental iron products, employees handled material such as but not limited to metal and welding gasses. Information and training as required by the standard had not been conducted, on or about 8/13/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332323)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340845262.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.