WESTERVILLE, OH —
OSHA Inspection: CP ROOFING AND SHEET METAL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CP ROOFING AND SHEET METAL in 5757 HUBER RIDGE ELEMENTARY, WESTERVILLE, OH 43081 (NAICS 238160). OSHA activity number 340845437.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CP ROOFING AND SHEET METAL
- Site address
- 5757 HUBER RIDGE ELEMENTARY
- City
- WESTERVILLE
- State
- OH
- ZIP
- 43081
- Mailing
- 1848 STETSON ROAD, COLUMBUS, OH 43232
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 D01
- Issued
- Jan 12, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: a. The employer has failed to submit abatement certification and documentation within ten days of the abatement date, November 4, 2015, for a violation of 29 CFR 1926.153(g), issued as citation 1, item 1, and described as follows: On or about August 13, 2015, located at Huber Ridge Elementary, employees were using propane tanks in order to heat roofing tar in a tar kettle while a propane tank was not secured to prevent tipping, thereby exposing the employees to a fire/struck-by hazard. b. The employer has failed to submit abatement certification and documentation within ten days of the abatement date, November 4, 2015, for a violation of 29 CFR 1926.501(b)(10), issued as citation 1, item 2, and described as follows: On or about August 13, 2015, located at Huber Ridge Elementary in Westerville, Ohio, employees were performing roofing work on a low-slope roof without fall protection, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
- — Z (O) $400
1926.153 G
- Issued
- Oct 23, 2015
- Abate by
- Nov 4, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.153(g): Containers and regulating equipment installed outside of buildings or structures. Containers shall be upright upon firm foundations or otherwise firmly secured. The possible effect on the outlet piping of settling shall be guarded against by a flexible connection or special fitting. a. On or about August 13, 2015, located at Huber Ridge Elementary, employees were using propane tanks in order to heat roofing tar in a tar kettle while a propane tank was not secured to prevent tipping, thereby exposing the employees to a fire/struck-by hazard.
Recent events (1)
- — Z (S) $2000
1926.501 B10
- Issued
- Oct 23, 2015
- Abate by
- Nov 4, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. a. On or about August 13, 2015, located at Huber Ridge Elementary in Westerville, Ohio, employees were performing roofing work on a low-slope roof without fall protection, thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
- — Z (S) $2000
1926.1053 B01
- Issued
- Oct 23, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. On or about August 13, 2015, located at Huber Ridge Elementary, employees were utilizing an extension ladder in order to gain access to the roof of the school. The ladder did not extend at least three feet above the upper landing surface, thereby exposing the employees to a fall hazard of approximately 13 feet, 7 inches.
Recent events (1)
- — Z (S) $2800
1926.1053 B05 I
- Issued
- Oct 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a. On or about August 13, 2015, located at Huber Ridge Elementary in Westerville, Ohio, employees were utilizing an extension ladder in order to gain access to the roof of the school while the ladder was not approximately one-quarter the working length, exposing the employees to a maximum fall hazard of 13 feet, 7 inches.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340845437.