BOW, NH —
OSHA Inspection: PITCO FRIALATOR INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PITCO FRIALATOR INC. in 552 ROUTE 3A, BOW, NH 03304 (NAICS 333319). OSHA activity number 340851021.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PITCO FRIALATOR INC.
- Site address
- 552 ROUTE 3A
- City
- BOW
- State
- NH
- ZIP
- 03304
- Mailing
- P.O. BOX 501, CONCORD, NH 03302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333319
- Employees
- 223
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Oct 30, 2015
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Blast Room - The employer had not provided a medical evaluation for a worker who was required to wear an airline respirator while performing abrasive blasting activities inside the enclosed booth.
Recent events (1)
- — Z (S) $3000
1910.242 B
- Issued
- Oct 30, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Outside Blast Room - Compressed air used for cleaning purposes was measured at 85 p.s.i.
Recent events (1)
- — Z (S) $2550
1910.244 B
- Issued
- Oct 30, 2015
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.244(b): Abrasive blast cleaning nozzle(s) were not equipped with an operating valve which had to be held open manually: Blast Room - The abrasive blasting nozzle switch was rigged to stay open without the operator holding it open manually.
Recent events (1)
- — Z (S) $3825
1910.303 G02 I
- Issued
- Oct 30, 2015
- Penalty
- Initial $3,188 · Current $3,188
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. Electrical Room - Employees were not protected from electrical shocks and burns when the electric panel cabinet did not include a faceplate, exposing live parts.
Recent events (1)
- — Z (S) $3188
1910.305 B02 I
- Issued
- Oct 30, 2015
- Penalty
- Initial $3,188 · Current $3,188
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Location: Electrical Room a. The Hoffman Fresh Air Pump control box had wires protruding from the bottom side of the unit. b. The alarm panel was missing its front cover, with exposed wires inside. c. The conduit box above the clock had no cover, with exposed wires inside. d. The outlet box near the alarm panel was missing its front cover.
Recent events (1)
- — Z (S) $3188
1910.303 G01
- Issued
- Oct 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Electrical Room - The space about the panel P1 which feeds the cafeteria AC unit was blocked by a step ladder leaning against it.
Recent events (1)
- — Z (O) $0
More inspections at Pitco Frialator INC.