DENVER, CO —
OSHA Inspection: U.S. POSTAL SERVICE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U.S. POSTAL SERVICE in 7755 E. 56TH STREET, DENVER, CO 80217 (NAICS 561431). OSHA activity number 340852672.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. POSTAL SERVICE
- Site address
- 7755 E. 56TH STREET
- City
- DENVER
- State
- CO
- ZIP
- 80217
- Mailing
- 7755 E. 56TH STREET, DENVER, CO 80217
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561431
- Employees
- 250
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II D
- Issued
- Dec 21, 2015
- Abate by
- Jan 19, 2016
- Penalty
- Initial $4,675 · Current $2,600 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing machines or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: a) U.S. Postal Service at 7755 E. 56th Street, Denver, CO 80217: On or before August 13, 2015, the energy control procedures for the Singulation and Sortation Induction Units (SSIUs) #3 and #4, did not clearly and specifically outline lockout tagout requirements in the following instances: -DELETED-1) The procedure stated in DNDC-001, Specific Energy Control Procedures for Standard Conveyors without Gravity Take-up Roller, allowed mechanical testing to verify that the machines will not start in steps 7(a), 7(b), and 7(c) (on pages 2 and 3), even when low air pressure could provide a false positive that the machines are de-energized. A return of air pressure could then re-energize the machine while maintenance employees are working on motors or rollers. The procedure does not require the verification of electrical deenergization through the use of a voltmeter. (Note DNDC-001 is used for partial shutdown, as compared to DNDC-022 which is used for complete shutdown);-DELETED- 2) DNDC-001 contained several inaccurate procedures for the SSIUs #3 and #4, such as a) referencing motor control panels (MCPs), when the SSIU motors do not have MCPs; b) referencing 120 and 220 volt circuits when the SSIU's have only 480 volt circuits; and c) failing to address individual motor control by unplugging the motor. -DELETED-3) The procedures stated in Volume B Section 3, Modified Alignment and Adjustment Procedures, Section 3.7.1.3.2, Conveyor Belt Speed Adjustment, in steps 6 and 7 on page 1, that the maintenance employee was to open the DCC door and turn the power disconnect switch to the "On" position, resulting in the potential activation of machines while the SSIUs # 3 and #4 are being worked on. The individual disconnects for the SSIUs were not capable of being locked out because they could be energized without removing the locking devices;-DELETED- -DELETED-4) The procedures failed to explain how to program Variable Frequency Drives (VFDs) while eliminating or controlling shock and arc flash hazards; and-DELETED- -DELETED-5) The procedures did not allow maintenance personnel to place their own lockouts on the energy controlling devices on the roof, in that they had to depend upon HVAC mechanics to lockout on the roof.-DELETED- Conditions exposed employees to amputation and electrical shock hazards.
Recent events (2)
- — I (O) $2600
- — Z (S) $4675
More inspections at U.S. Postal Service
View U.S. Postal Service's full OSHA safety record →
More inspections in this industry (NAICS 561431)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340852672.