OSHA Inspection: ABELARDO DELEON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ABELARDO DELEON in 21627 SILVER BURCH DR., HOUSTON, TX 77073 (NAICS 238130). OSHA activity number 340852789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Abelardo Deleon — free Get an email when a new federal OSHA severe-injury report for Abelardo Deleon is published. One employer, no account, unsubscribe in one click.
Establishment
ABELARDO DELEON
Site address
21627 SILVER BURCH DR.
City
HOUSTON
State
TX
ZIP
77073
Mailing
8130 WARREN RD., HOUSTON, TX 77040
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.403 B01

Other-than-serious 1 instance 1 exposed
Issued
Oct 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:    On or about August 17, 2015 at the construction site where an employee was exposed to electrical hazards when working with an electrical cord where the insulation around one of the blades had been burned causing the plastic to bubble up around the blade.
Recent events (1)
  • — Z (O) $0

1926.404 F06

Other-than-serious 2 instances 1 exposed
Issued
Oct 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a. On or about August 17, 2015, at the construction site where an employee was exposed to electrical hazards while operating a Milwaukee brand circular saw where the ground prong was missing.     b. On or about August 17, 2015, at the construction site where an employee was exposed to electrical hazards while using an electrical extension cord where the ground wire had detached from the plug.
Recent events (1)
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 2 instances 1 exposed
Issued
Oct 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a.  On or about August 17, 2015, at the construction site where an employee was exposed to electrical hazards while using an extension cord that had the outer insulation pulled back from the female end of the extension cord allowing strain to be applied to the terminal ends in the plug.    b.  On or about August 17, 2015, at the construction site where an employee was exposed to electrical hazards while operating a Sunbeam brand microwave that had the outer insulation pulled back from the point where the cord comes out from the microwave allowing strain to be applied to the terminal ends in the plug.