VALLEY CENTER, CA —
OSHA Inspection: KINSMAN CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KINSMAN CONSTRUCTION, INC. in ALL TRIBES CHATER SCHOOL PROJECT 34320 VALLEY CENTER ROAD, VALLEY CENTER, CA 92082 (NAICS 236220). OSHA activity number 340853274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KINSMAN CONSTRUCTION, INC.
- Site address
- ALL TRIBES CHATER SCHOOL PROJECT 34320 VALLEY CENTER ROAD
- City
- VALLEY CENTER
- State
- CA
- ZIP
- 92082
- Mailing
- 6711 NANCY RIDGE DRIVE, SAN DIEGO, CA 92121
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Sep 24, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a) On August 17, 2015, near the north end and west side interior of the project, there was no fall protection for employees around the 6 foot, 8 inch by 2 foot, 8 inch opening in the attic floor that was used to access the attic. Employees that used the opening to access the attic area were exposed to the hazard of falling from a height of about 12 feet, 1 inch to the concrete below. (b) On August 17, 2015, near the north end and east side interior of the project, there was no fall protection for employees around a 6 foot, 8 inch by 3 foot opening in the attic floor. Employees that worked next to the opening were exposed to the hazard of falling from a height of about 12 feet, 1 inch to the concrete below.
Recent events (2)
- — I (S) $1360
- — Z (S) $1360
1926.701 B
- Issued
- Sep 24, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement: On August 17, 2015, and for about one week prior, at the west side exterior of the project, there was no guarding for about 60, number 4 rebar, that protruded vertically about 16 inches above the CMUs. Employees, that walked and worked next to the rebar to dig a trench for electrical conduit, were exposed to the hazard of striking against the rebar.
Recent events (2)
- — I (O) $0
- — Z (S) $1020
More inspections at Kinsman Construction, INC.
View Kinsman Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340853274.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.