Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENERGY EXPEDITERS, INC.

Programmed Related inspection · Health discipline

On , OSHA opened a programmed Related health inspection of ENERGY EXPEDITERS, INC. in 736 NORTH 4TH STREET, MILWAUKEE, WI 53203 (NAICS 238220). OSHA activity number 340858091.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energy Expediters, INC. — free Get an email when a new federal OSHA severe-injury report for Energy Expediters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
736 NORTH 4TH STREET
City
MILWAUKEE
State
WI
ZIP
53203
Mailing
7235 W NATIONAL AVE, WEST ALLIS, WI 53214
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 27, 2016
Abate by
Feb 16, 2016
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (Construction Reference 1926.103)  (a) The required written portions of a respirator program were not established prior to an employee being allowed to use an elastomeric respirator.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 27, 2016
Abate by
Feb 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)  (a) An employee was allowed to use an elastomeric respirator and was not medically evaluated prior to the voluntary use of the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 27, 2016
Abate by
Feb 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (Construction Reference 1926.103)  (a) An employee allowed to voluntarily use an elastomeric respirator was not trained on at least the contents of Appedix D of the Respirator standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Energy Expediters, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340858091.