EL PASO, TX —
OSHA Inspection: SUMMIT 11 INVESTMENT GROUP, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUMMIT 11 INVESTMENT GROUP, LLC in 325 NORTH KANSAS STREET, EL PASO, TX 79901 (NAICS 236220). OSHA activity number 340858208.
Where did this inspection happen?
- Establishment
- SUMMIT 11 INVESTMENT GROUP, LLC
- Site address
- 325 NORTH KANSAS STREET
- City
- EL PASO
- State
- TX
- ZIP
- 79901
- Mailing
- 300 MAIN SUITE 700, EL PASO, TX 79901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 55
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.405 B02
- Issued
- Abate by
- Penalty
- Initial $3570.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: Hotel renovation site: On or about February 6, 2015 and at prior times thereto, all electrical outlet boxes in the hallway from the 5th through 12th floors were energized and missing the faceplate covers. This condition exposed the employees to electrical burn and/or shock hazards.
Recent events (2)
- — I (S) $1800
- — Z (S) $3570
1926.405 G01 III C
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(C): Flexible cords and cables were run through doorways, windows, or similar openings: Hotel renovation site: On or about February 6, 2015 and at prior times thereto, two extension cords going from hallway to the pool area were pinched between the door and frame. This condition exposed the employees to electrical burns and shock hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2975
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $595.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Hotel renovation site: On or about October 6, 2015, and at times prior thereto, employees working throughout the building extension cords plugged into one another (daisy-chained). This condition exposed employees to electrical burns and shock hazards. a) Ground floor check-in room had 3 in extension cords plugged together. b) Fifth floor pool area and hallway; employees working had 2 extension cords plugged together. c) Eleventh floor hallway: employees working had 2 extension cords plugged together.
Recent events (2)
- — I (O) $400
- — Z (O) $595
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340858208.