Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INHANCE TECHNOLOGIES LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INHANCE TECHNOLOGIES LLC in 1 CAL TURNER JR, HOMERVILLE, GA 31634 (NAICS 326121). OSHA activity number 340859156.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inhance Technologies LLC — free Get an email when a new federal OSHA severe-injury report for Inhance Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
1 CAL TURNER JR
City
HOMERVILLE
State
GA
ZIP
31634
Mailing
CORPORATE HEADQUARTERS 16223 PARK ROW, SUITE 100, HOUSTON, TX 77084
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326121
Employees
11
Ownership type
A

7 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $4,209 · Current $2,525 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.   a) At the storage area for metal bins, on or about and at times prior to August 12, 2015, the employer allowed employees to operate propane forklifts in an area which had a portion of the floor in disrepair, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2525.4
  • — Z (S) $4209

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $3,366 · Current $2,020 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) At the propane dispensing station, on or about and at times prior to August 12, 2015, the employer failed to supply employees with eye protection (i.e. safety glasses or chemical splash goggles), exposing employees to skin burns from contact with liquid propane.
Recent events (2)
  • — I (S) $2019.6
  • — Z (S) $3366

1910.178 L03 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $6,930 · Current $4,158 Reduced
29 CFR 1910.178(l)(3)(i)(A): Powered industrial truck operators did not receive initial training on operating instructions, warnings, and precautions for the types of truck the operator would be authorized to operate  a)At the facility, on or about and at times prior to August 12, 2015, the employer failed to ensure that forklift operators were trained in safe operations including but not limited to not operating forklifts in need of repair (i.e. overheating and leaking fluids), exposing employees to struck-by and crush-by hazards.
Recent events (2)
  • — I (S) $4158
  • — Z (S) $6930

1910.178 L06

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a) At the facility, on or about and at times prior to August 12, 2015, the employer did not certify the training of all employees who operated powered industrial trucks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Jan 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s)   a) At the facility, on or about and at times prior to August 12, 2015, the employer allowed employees to operate a powered industrial truck that that was overheating and leaking fluids, exposing employees to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 11, 2015
Penalty
Initial $2,525 · Current $1,515 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) At the facility, on or about August 12, 2015, and at times prior to, there were two unused openings on the table top conveyor electrical control switch box, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1515
  • — Z (S) $2525

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) At the facility, on or about and at times prior to August 12, 2015, an extension cord was used to power the table top conveyor in lieu of using fixed wiring of a structure, resulting in an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Inhance Technologies LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340859156.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.