WISCONSIN DELLS, WI —
OSHA Inspection: MT. OLYMPUS ENTERPRISES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MT. OLYMPUS ENTERPRISES, INC. in 1881 WISCONSIN DELLS PARKWAY, WISCONSIN DELLS, WI 53965 (NAICS 713110). OSHA activity number 340863380.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MT. OLYMPUS ENTERPRISES, INC.
- Site address
- 1881 WISCONSIN DELLS PARKWAY
- City
- WISCONSIN DELLS
- State
- WI
- ZIP
- 53965
- Mailing
- P.O. BOX 267, WISCONSIN DELLS, WI 53965
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713110
- Employees
- 157
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 20, 2015
- Abate by
- Feb 14, 2016
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures had not been be developed and documented for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: The employer had not developed and documented energy control procedures for theme park equipment such as, but not limited to, roller coasters and other park rides.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.147 C05 I
- Issued
- Nov 20, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: The employer had not provided lockout/tagout hardware to all employees who perform servicing and/or maintenance activities on roller coasters and park rides.
Recent events (2)
- — I (S) $5000
- — Z (S) $5000
1910.147 C07 I
- Issued
- Nov 20, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls was acquired by employees: Employee(s) who engage in servicing and/or maintenance activities on roller coasters and theme park rides had not received training on the purpose and function of the employer's lockout/tagout program that included providing knowledge and skills required for the safe application and usage of lockout/tagout equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $5000
1910.335 A01 I
- Issued
- Nov 20, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: On or about August 19, 2015 employee(s) who performed electrical maintenance and troubleshooting on energized circuits 408 volts and less were not provided with electrical protective equipment.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.132 D02
- Issued
- Nov 20, 2015
- Abate by
- Feb 14, 2016
- Penalty
- Initial $1,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation had been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: On or about August 8, 2015 the employer had not performed and documented a workplace hazard assessment for personal protective equipment (PPE).
Recent events (2)
- — I (O) $0
- — Z (O) $1000
1910.147 F03 I
- Issued
- Nov 20, 2015
- Abate by
- Feb 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance was performed by a crew, craft, department or other group, they did not utilize a procedure which afforded the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device: Group lockout procedures were not utilized during maintenance activities on roller coasters and park rides that involved multiple employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 713110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340863380.