OSHA Inspection: FIDELIS VETERAN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIDELIS VETERAN CONSTRUCTION, INC. in BLDG 5 AND 6 3400 LEBANON PIKE, MURFREESBORO, TN 37129 (NAICS 238210). OSHA activity number 340864990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fidelis Veteran Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Fidelis Veteran Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 5 AND 6 3400 LEBANON PIKE
City
MURFREESBORO
State
TN
ZIP
37129
Mailing
1220 NORTH ROUSE AVE, BOZEMAN, MT 59715
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
13
Ownership type
A

2 citations on file for this inspection.

1926.20 B03

Other-than-serious 1 instance 3 exposed
Issued
Sep 30, 2015
Abate by
Oct 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation:  a) Emergency Electrical Room  Bldg. 5 (3400 Lebanon Pike) - On or about 8/20/2015, employees were exposed to shock hazards when a damaged extension cord was not tagged out and discarded.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 3 exposed
Issued
Sep 30, 2015
Abate by
Oct 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) Electrical Room for Bldg. 5/6 (3400 Lebanon Pike) - On or about 8/20/2015, employees were exposed to shock hazards when the flexible cord on the temporary transformer did not have strain relief.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).