SAN ANTONIO, TX —
OSHA Inspection: CALIBER COLLISION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CALIBER COLLISION in 4906 BLANCO RD., SAN ANTONIO, TX 78212 (NAICS 811121). OSHA activity number 340866185.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALIBER COLLISION
- Site address
- 4906 BLANCO RD.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78212
- Mailing
- 4906 BLANCO RD., SAN ANTONIO, TX 78212
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 2100
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.253 B04 I
- Issued
- Jan 22, 2016
- Abate by
- Jan 28, 2016
- Penalty
- Initial $3,300 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or near any other substance likely to cause or accelerate fire; or in an acetylene generator: MAIN MECHANICAL REPAIR BAY: On or about August 19, 2015, and at times prior thereto, employees were exposed to the fire hazard of storing combustible material such as fuel gas near oxygen containers.
Recent events (2)
- — I (S) $2475
- — Z (S) $3300
1910.305 B01 II
- Issued
- Jan 22, 2016
- Abate by
- Feb 6, 2016
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: PAINT AREA: On or about August 19, 2015, and at times prior thereto, employees were exposed to the electrical shock hazard of an unused openings in the light panel.
Recent events (2)
- — I (S) $0
- — Z (S) $3300
1910.304 G05
- Issued
- Jan 22, 2016
- Abate by
- Jan 28, 2016
- Penalty
- Initial $3,300 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: PAINT AREA: On or about August 19, 2015, and at times prior thereto, employees were exposed to the electrical shock hazard of an ungrounded plug used in the 110-120 volt floor fan.
Recent events (2)
- — I (S) $2475
- — Z (S) $3300
1910.305 G02 II
- Issued
- Jan 22, 2016
- Abate by
- Jan 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: PAINT AREA: On or about August 19, 2015, and at times prior thereto, employees were exposed an electrical shock hazard from a spliced cord used in the 110-120 volt floor fan.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Caliber Collision
View Caliber Collision's full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340866185.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.