NELSONVILLE, OH —
OSHA Inspection: STRUCTURAL SYSTEMS REPAIR GROUP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STRUCTURAL SYSTEMS REPAIR GROUP in 30 PUBLIC SQUARE, NELSONVILLE, OH 45764 (NAICS 238910). OSHA activity number 340866680.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRUCTURAL SYSTEMS REPAIR GROUP
- Site address
- 30 PUBLIC SQUARE
- City
- NELSONVILLE
- State
- OH
- ZIP
- 45764
- Mailing
- 2428 STANTON AVE, CINCINNATI, OH 45206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 230
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.350 A10
- Issued
- Oct 8, 2015
- Abate by
- Oct 21, 2015
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. In the building where work was being performed, the employer had stored oxygen and acetalene together on a cart and tdid not separate the cylinders by 20 feet, thereby exposing employees to a fire/explosion hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3825
1926.1431 G01 I
- Issued
- Oct 8, 2015
- Abate by
- Oct 21, 2015
- Penalty
- Initial $3,825 · Current $5,738
General-duty citation text
29 CFR 1926.1431(g)(1)(i): Hooks used in the connection between the hoist line and the personnel platform (including hooks on overhaul ball assemblies, lower load blocks, bridle legs, or other attachment assemblies or components) must be: 29 CFR 1926.1431(g)(1)(ii)(A): A bolt, nut and retaining pin, in place: a. At the front of the building where employees were hoisted in a personnel platform, the overhead hook, which had the fall protection connected in the hook, did not have a bolt, nut or retaining pin to prevent a spin out of the hook.
Recent events (2)
- — I (S) $5737.5
- — Z (S) $3825
1926.1431 K10 I
- Issued
- Oct 8, 2015
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1431(k)(10)(i): Except over water, employees occupying the personnel platform must be provided and use a personal fall arrest system. The system must be attached to a structural member within the personnel platform. When working over or near water, the requirements of 29 CFR 1926.106 apply: a. At the front of the building where employees were working from a personnel platform to install knife plates on the inside of a burned out building, the fall protection system was attached to a sling attached outside the personnel platform, thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3825
More inspections in this industry (NAICS 238910)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340866680.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.