OSHA Inspection: BROOKS REMODELING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BROOKS REMODELING in BAILEY'S AUTO REPAIR, SKELTON, WV 25919 (NAICS 238170). OSHA activity number 340867191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brooks Remodeling — free Get an email when a new federal OSHA severe-injury report for Brooks Remodeling is published. One employer, no account, unsubscribe in one click.
Establishment
BROOKS REMODELING
Site address
BAILEY'S AUTO REPAIR
City
SKELTON
State
WV
ZIP
25919
Mailing
P O BOX 661, MAC ARTHUR, WV 25873
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:  a.)  Brooks Remodeling, Bailey's Auto Repair, Skelton WV:  On or about 08/21/15, the 120 volt 15 amp receptacle outlets in the garage were not provided with GFCI protection when used to supply power to an extension cord and Makita circular saw.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a.)  Brooks Remodeling, Bailey's Auto Repair, Skelton WV:  On or about 08/21/15, employees laying sheeting on a 4/12 sloped roof were not protected from falling 18' to the ground.  ABATEMENT DOCUMENTATION IS REQUIRED.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  a.)  Brooks Remodeling, Bailey's Auto Repair, Beckley WV:  On or about 08/21/15, employees were not provided with training in fall hazards prior to being required to work on a roof approximately 18' above the ground.  ABATEMENT DOCUMENTATION IS REQUIRED.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a.)  Brooks Remodeling, Bailey's Auto Repair, Skelton WV:  On or about 08/21/15, the extension ladder used to access the roof was not properly extended at least 3' above the landing surface.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.1060 A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.  a.)  Brooks Remodeling, Bailey's Auto Repair, Skelton WV:  On or about 08/21/15, employees using a Werner extension ladder to access the roof were not trained in ladder safety.  ABAEMENT CERTIFICATION IS REQUIRED.