SARANAC LAKE, NY —
OSHA Inspection: STENDER MASONRY
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of STENDER MASONRY in 68 DORSEY STREET, SARANAC LAKE, NY 12983 (NAICS 238140). OSHA activity number 340871334.
Where did this inspection happen?
- Establishment
- STENDER MASONRY
- Site address
- 68 DORSEY STREET
- City
- SARANAC LAKE
- State
- NY
- ZIP
- 12983
- Mailing
- 105 COLD BROOK ROAD, VERMONTVILLE, NY 12989
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.106 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.106(a): Employee(s) working over or near water where the danger of drowning existed, were not provided with U.S. Coast Guard approved life jacket(s) or buoyant work vest(s): a) At the jobsite, over water, on or about 8/20/15: Employees were engaged in the construction of and working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2000
1926.106 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.106(c): Ring buoys with at least 90 feet of line were not provided and readily available for emergency rescue operations: a) At the jobsite, over water, on or about 8/20/15: Employees were working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests and without being provided a ring buoy with at least 90 feet of line. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.106 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.106(d): A lifesaving skiff was not immediately available at locations where employees were working over or adjacent to water: a) At the jobsite, over water, on or about 8/20/15: Employees were working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests, without being provided a ring buoy with at least 90 feet of line, and without being provided a skiff for rescue operations. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) At the jobsite, on or about 8/20/15: Employees were engaged in the construction of and working on a scaffold system that was lacking in guardrail components, did not have appropriate access, and was constructed over water without the water survival and lifesaving items needed for that configuration. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) At the jobsite, on or about 8/20/15: Employees were climbing the scaffold frames to access and to egress the system. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. a) At the jobsite, on or about 8/20/15: Employees were working on a scaffold system where cross bracing provided a functional mid-rail, however no top-rail was provided exposing workers to a fall potential of 15 feet to ground. b) At the jobsite, on or about 8/20/15: Employees were working on a scaffold system where a material plank provided a functional mid-rail, however no top-rail was provided exposing workers to a fall potential of 18 feet to ground. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340871334.