Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STENDER MASONRY

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of STENDER MASONRY in 68 DORSEY STREET, SARANAC LAKE, NY 12983 (NAICS 238140). OSHA activity number 340871334.

Watch Stender Masonry — free Get an email when a new federal OSHA severe-injury report for Stender Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
STENDER MASONRY
Site address
68 DORSEY STREET
City
SARANAC LAKE
State
NY
ZIP
12983
Mailing
105 COLD BROOK ROAD, VERMONTVILLE, NY 12989
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.106 A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.106(a): Employee(s) working over or near water where the danger of drowning existed, were not provided with U.S. Coast Guard approved life jacket(s) or buoyant work vest(s):    a)  At the jobsite, over water, on or about 8/20/15:  Employees were engaged in the construction of and working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1926.106 C

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.106(c): Ring buoys with at least 90 feet of line were not provided and readily available for emergency rescue operations:    a)  At the jobsite, over water, on or about 8/20/15:  Employees were working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests and without being provided a ring buoy with at least 90 feet of line.        Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.106 D

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.106(d): A lifesaving skiff was not immediately available at locations where employees were working over or adjacent to water:    a)  At the jobsite, over water, on or about 8/20/15:  Employees were working on a scaffold system that was cantilevered over the bank of the Saranac River without being provided Life Jackets or buoyant work vests, without being provided a ring buoy with at least 90 feet of line, and without being provided a skiff for rescue operations.        Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  a)  At the jobsite, on or about 8/20/15:  Employees were engaged in the construction of and working on a scaffold system that was lacking in guardrail components, did not have appropriate access, and was constructed over water without the water survival and lifesaving items needed for that configuration.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a)  At the jobsite, on or about 8/20/15:  Employees were climbing the scaffold frames to access and to egress the system.          Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph.  a)  At the jobsite, on or about 8/20/15:  Employees were working on a scaffold system where cross bracing provided a functional mid-rail, however no top-rail was provided exposing workers to a fall potential of 15 feet to ground.      b)  At the jobsite, on or about 8/20/15:  Employees were working on a scaffold system where a material plank provided a functional mid-rail, however no top-rail was provided exposing workers to a fall potential of 18 feet to ground.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340871334.